SIKESTON, MO —
OSHA Inspection: TETRA PAK MATERIALS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TETRA PAK MATERIALS, LLC in 2200 EAST MALONE AVE., SIKESTON, MO 63801 (NAICS 322221). OSHA activity number 343300919.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TETRA PAK MATERIALS, LLC
- Site address
- 2200 EAST MALONE AVE.
- City
- SIKESTON
- State
- MO
- ZIP
- 63801
- Mailing
- 2200 EAST MALONE AVE., SIKESTON, MO 63801
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322221
- Employees
- 130
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E02 IV D
- Issued
- Jul 25, 2018
- Penalty
- Initial $4,240 · Current $4,240
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: In the ink room, ethyl acetate was drawn from a 55 gal. drum without a self-closing valve.
Recent events (1)
- — Z (S) $4240
1910.106 E06 I
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: In the ink room, ethyl acetate was drawn from a 55 gal. drum without the drum attached to a grounding cable.
Recent events (1)
- — Z (S) $0
1910.106 E09 III
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: In the ink room, on July 13, 2018, a safety waste receptacle was overfilled with used rags, preventing the lid from closing, contributing to vapors being released into the room.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Jul 25, 2018
- Penalty
- Initial $7,068 · Current $7,068
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by contact with gears when adjusting a press roller: In the press department, where operators infrequently were required to adjust a roller for installation of a new adhesive plate, there was inadequate guarding to prevent contact with the roller gears.
Recent events (1)
- — Z (S) $7068
More inspections at Tetra PAK Materials, LLC
View Tetra PAK Materials, LLC's full OSHA safety record →
More inspections in this industry (NAICS 322221)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343300919.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.