OSHA Inspection: APPLE ROOFING CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of APPLE ROOFING CORP in MANCHESTER-SHORTSVILLE HIGH SCHOOL MAIN STREET, SHORTSVILLE, NY 14548 (NAICS 238160). OSHA activity number 343303871.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apple Roofing Corp — free Get an email when a new federal OSHA severe-injury report for Apple Roofing Corp is published. One employer, no account, unsubscribe in one click.
Establishment
APPLE ROOFING CORP
Site address
MANCHESTER-SHORTSVILLE HIGH SCHOOL MAIN STREET
City
SHORTSVILLE
State
NY
ZIP
14548
Mailing
6720 COMMERCE BLVD, SYRACUSE, NY 13211
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Deleted Willful Gravity 5 3 instances 12 exposed
Issued
Jan 11, 2019
Abate by
Jan 17, 2019
Penalty
Initial $48,777 · Current $0 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.  a)  At the jobsite, on the upper roof, on or about 7/13/18:  Two workers were fitting membrane around a drain, outside the warning line, 10 feet from the lower level, and without a monitor present.  b)  At the jobsite, on the lower roof, on or about 7/13/18:  A worker moved guardrail to receive a 55 gallon drum of adhesive that was delivered to the roof by a fork truck.  This worker was not protected from falling 20 feet to ground.  c)  At the jobsite, on the upper roof, on or about 7/13/18:  Twelve workers were performing roofing work in close proximity to 15 unprotected skylights, and without fall protection of any kind.
Recent events (3)
  • — J (W) $0
  • — C (W) $48777
  • — Z (W) $48777

View Apple Roofing Corp's full OSHA safety record →