Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRISTATE STEEL FIRE PROOFING

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of TRISTATE STEEL FIRE PROOFING in 350 HENRY ST., BROOKLYN, NY 11201 (NAICS 238310). OSHA activity number 343312724.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tristate Steel Fire Proofing — free Get an email when a new federal OSHA severe-injury report for Tristate Steel Fire Proofing is published. One employer, no account, unsubscribe in one click.
Site address
350 HENRY ST.
City
BROOKLYN
State
NY
ZIP
11201
Mailing
169 CLASSON AVE., BROOKLYN, NY 11205
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
8
Ownership type
A

5 citations on file for this inspection.

1910.134 C02 II

Other-than-serious Gravity 5 4 instances 4 exposed
Issued
Dec 21, 2018
Abate by
Feb 11, 2019
Penalty
Initial $2,217 · Current $2,000 Reduced

Hazardous substances P104S103

29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (Construction Reference 1926.103)     (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not establish and implement the applicable elements of the respiratory protection program. The condition was noted on or about July 7, 2018.      NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Recent events (3)
  • — F (O) $2000
  • — C (S) $2217
  • — Z (S) $2217

1910.134 D01 III

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Dec 21, 2018
Abate by
Feb 11, 2019
Penalty
Initial $0 · Current $0

Hazardous substances P104S103

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (Construction Reference 1926.103)    In the alternative  29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were exposed to chemical hazards while spraying CAFCO Blaze-Shield II fire resistive material which contains Portland Cement, Quartz (SiO2) throughout the building. The employer did not identify and evaluate the respiratory hazard. The condition was noted on or about July 7, 2018.     NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 E01

Other-than-serious Gravity 5 4 instances 4 exposed
Issued
Dec 21, 2018
Abate by
Feb 11, 2019
Penalty
Initial $0 · Current $0

Hazardous substances P104S103

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)     (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not provide medical evaluation . The condition was noted on or about July 7, 2018.        NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 H03 II A

Other-than-serious Gravity 5 4 instances 4 exposed
Issued
Dec 21, 2018
Abate by
Feb 11, 2019
Penalty
Initial $0 · Current $0

Hazardous substances P104S103

29 CFR 1910.134(h)(3)(ii)(A): Respirator inspections did not include a check of respirator function, tightness of connections, and the condition of the various parts including, but not limited to, the facepiece, head straps, valves, connecting tube, and cartridges, canisters or filters:  (Construction Reference 1926.103)    (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not develop and implement a maintenance and care schedule of respirators. The condition was noted on or about July 7, 2018.       NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 K01

Other-than-serious Gravity 5 4 instances 4 exposed
Issued
Dec 21, 2018
Abate by
Feb 11, 2019
Penalty
Initial $0 · Current $0

Hazardous substances P104S103

29 CFR 1910.134(k)(1): 29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii):(Construction Reference 1926.103)     (a) Tristate Steel Fire Proofing employees', working at 350 Henry St. Brooklyn, NY 11201, were observed wearing 3M, Honeywell, and North elastomeric half-face tight-fitting respirators while spraying CAFCO Blaze-Shield II fire resistive material. The employer did not develop and implement a training and information plan. The condition was noted on or about July 7, 2018.       NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

View Tristate Steel Fire Proofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343312724.