Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ABB OPTICAL GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ABB OPTICAL GROUP in 4 SKYLINE DRIVE, HAWTHORNE, NY 10532 (NAICS 446130). OSHA activity number 343315941.

Watch ABB Optical Group — free Get an email when a new federal OSHA severe-injury report for ABB Optical Group is published. One employer, no account, unsubscribe in one click.
Establishment
ABB OPTICAL GROUP
Site address
4 SKYLINE DRIVE
City
HAWTHORNE
State
NY
ZIP
10532
Mailing
4 SKYLINE DRIVE, HAWTHORNE, NY 10532
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
446130
Employees
1300
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $9239.00 · Current $5952.00 Reduced
29 CFR 1910.147(c)(1): 29 CFR 1910.147(c)(1):  The employer did not establish a program consisting of an energy control procedures and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4).    Location: Basement (Manufacturing Department)    On or about July 6, 2018, the employer failed to protect each employee by developing, documenting and utilizing procedures for the control of potential hazardous energy. Employees performing maintenance (cleaning, unjamming) on multiple types of equipment were exposed to contact with electrical current, and caught in hazards.
Recent events (2)
  • — I (S) $5952
  • — Z (S) $9239

1910.147 C05 II

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $9239.00 · Current $5952.00 Reduced
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices shall be singularly identified; shall be the only devices(s) used for controlling energy; shall not be used for other purposes; and shall meet the following requirements:    On or about 7/6/28, employees were exposed to electrical hazards due to Lockout devices and tagout devices not being singularly identified; were not the only devices used for controlling energy.
Recent events (2)
  • — I (S) $5952
  • — Z (S) $9239

View ABB OPTICAL GROUP's full OSHA safety record →

OPT, LLC