OVERLAND PARK, KS —
OSHA Inspection: D N D STATUARY & U-CART CONCRETE
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of D N D STATUARY & U-CART CONCRETE in 3415 MERRIAM DR, OVERLAND PARK, KS 66211 (NAICS 327390). OSHA activity number 343318028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D N D STATUARY & U-CART CONCRETE
- Site address
- 3415 MERRIAM DR
- City
- OVERLAND PARK
- State
- KS
- ZIP
- 66211
- Mailing
- 3415 MERRIAM DR, OVERLAND PARK, KS 66211
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.219 F03
- Issued
- Aug 30, 2018
- Abate by
- Sep 26, 2018
- Penalty
- Initial $2,217 · Current $1,552 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Employees engaged in production activities at the mixer were exposed to caught-in hazards in that the chain and sprocket was not guarded.
Recent events (2)
- — I (S) $1551.9
- — Z (S) $2217
1910.303 B07 I
- Issued
- Aug 30, 2018
- Abate by
- Sep 26, 2018
- Penalty
- Initial $2,217 · Current $1,552 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. Employees engaged in production activities at the mixer were exposed to electrical hazards in that the unused opening on the face of the electrical control box was not closed exposing employees to live conductors.
Recent events (2)
- — I (S) $1551.9
- — Z (S) $2217
1910.1200 E01
- Issued
- Aug 30, 2018
- Abate by
- Oct 18, 2018
- Penalty
- Initial $2,217 · Current $1,552 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Employees engaged in production activities through the facility were exposed to health hazards in that a comprehensive written hazard communication program had not been developed and implemented which included but is not limited to: employee training, employee access to safety data sheets, and container labeling. Hazardous chemicals used at the facility include muriatic acid and Portland cement.
Recent events (2)
- — I (S) $1551.9
- — Z (S) $2217
1910.141 D01
- Issued
- Aug 30, 2018
- Abate by
- Sep 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition: The restroom at the facility was not maintained in a sanitary condition.
Recent events (2)