Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R. A. GLANCY & SONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R. A. GLANCY & SONS, INC. in 1 NORTH JEFFERSON AVENUE, CANONSBURG, PA 15317 (NAICS 237990). OSHA activity number 343319018.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R. a. Glancy & Sons, INC. — free Get an email when a new federal OSHA severe-injury report for R. a. Glancy & Sons, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 NORTH JEFFERSON AVENUE
City
CANONSBURG
State
PA
ZIP
15317
Mailing
2361 VENTURE DRIVE, GIBSONIA, PA 15044
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 25, 2018
Abate by
Jul 31, 2018
Penalty
Initial $3,298 · Current $2,144 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a)  Jobsite:  On or about July 19, 2018, the grounding pin to the Milwaukee hand held 7 1/4 inch circular saw was missing.
Recent events (2)
  • — I (S) $2143.7
  • — Z (S) $3298

1926.405 A02 II I

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2018
Abate by
Jul 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  (a)  On or about July 21, 2018, the employer had two electrical cords running across a roadway and they were not protected from vehicular damage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View R. a. Glancy & Sons, INC.'s full OSHA safety record →