Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIRECT COLOR SYSTEMS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DIRECT COLOR SYSTEMS in 99 HAMMER MILL ROAD, ROCKY HILL, CT 06067 (NAICS 333244). OSHA activity number 343320826.

Watch Direct Color Systems — free Get an email when a new federal OSHA severe-injury report for Direct Color Systems is published. One employer, no account, unsubscribe in one click.
Site address
99 HAMMER MILL ROAD
City
ROCKY HILL
State
CT
ZIP
06067
Mailing
99 HAMMER MILL ROAD, ROCKY HILL, CT 06067
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333244
Employees
56
Ownership type
A

7 citations on file for this inspection.

1910.106 D03 II A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4398.00 · Current $2199.00 Reduced
29 CFR 1910.106(d)(3)(ii)(a): Metal cabinets were not deemed to be in compliance as they were not constructed with the bottom, top, door, and sides of cabinet at least No. 18 gage sheet iron and double walled with 1 1/2-inch air space; the joints riveted, welded, or made tight by some equally effective means; the door provided with a three-point lock; and the door sill raised at least 2 inches above the bottom of the cabinet:  APPLICATION    On, or about July 23, 2018, the metal cabinet used to store flammable liquids such as, but not limited to toluene, was not compliant because the cabinet was stainless steel and not constructed with at least No. 18 gauge sheet iron,  it was a single wall and not double walled, the joints had visible openings and were not tight, and the door had a two point lock and not the required three-point lock; and or the door sill was not raised at least 2 inches above the bottom of the cabinet. The door sill was not raised.
Recent events (2)
  • — I (S) $2199
  • — Z (S) $4398

1910.106 E09 III

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3298.00 · Current $1649.00 Reduced
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  TECH OUT    On, or about July 23, 2018, rags impregnated with ISOCLEAN, which contained Propan-2-ol, a flammable chemical (flashpoint 53 Fahrenheit), were discarded in a plastic, uncovered waste basket.
Recent events (2)
  • — I (S) $1649
  • — Z (S) $3298

1910.305 G02 III

Serious Gravity 1 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $3298.00 · Current $1649.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    QUALITY    On, or, about July23, 2018, a drop down cord and plug outlet, used to energized computers and accessories, was not provided strain relief.
Recent events (2)
  • — I (S) $1649
  • — Z (S) $3298

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4398.00 · Current $2199.00 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:    FACILITY    On, or about July 23, 2018, the employer failed to develop and implement a written hazard communication program when employees worked with chemicals, such as, but not limited to 99% IPA wipes, which contained isopropyl alcohol and was used as a cleaner.
Recent events (2)
  • — I (S) $2199
  • — Z (S) $4398

1910.1200 F06 II

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:     TECH OUT     On, or about July 23, 2018, a spray bottle, reported to contain ISO CLEAN, and contained isopropyl alcohol, was not labeled tagged or marked with its product identifier and words, pictures and or symbols which provide general information on the hazards of the chemical, such as flammability.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 III

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:  On, or about July 23, 2018, the employer failed to train employees on the following:    a) The measures employees should use to protect themselves, including the proper disposal of rags and other materials impregnated with flammable chemicals, such as isopropyl alcohol found in ISOCLEAN, used in TECH OUT.    b) The measures employees should use to protect themselves from vapors generated from chemicals such as toluene, used in TESTING.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Other-than-serious 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    On, or about July 23, 2018, the required working space around the following electric equipment was used for storage:    a) A chair and two bags of paper was stored within three feet of the electrical panel near the SOUTH emergency exit doors.    b) An inoperable Crown forklift truck was stored within three feet of the electrical panel in the warehouse.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343320826.