OSHA Inspection: GATEWAY PRINTING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GATEWAY PRINTING COMPANY, INC. in 925 PACIFIC AVE, BREMEN, GA 30110 (NAICS 323111). OSHA activity number 343321626.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gateway Printing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Gateway Printing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
925 PACIFIC AVE
City
BREMEN
State
GA
ZIP
30110
Mailing
925 PACIFIC AVE, BREMEN, GA 30110
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
18
Ownership type
A

11 citations on file for this inspection.

1910.106 D05 VI A

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 23, 2019
Abate by
Feb 19, 2019
Penalty
Initial $4,546 · Current $3,150 Reduced
29 CFR 1910.106(d)(5)(vi)(a): When the storage building was located 50 feet (15.2 m) or less from a building or line of adjoining property that could be built upon, the exposing wall was not a blank wall having a fire-resistance rating of at least 2 hours:    a) Outside Flammable Storage Building: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that the walls of the storage building provided did not have a fire-resistance rating of at least 2 hours when storing two 55 gallon drums of #1 Network Pro 100 solvent and a 5 gallon plastic container of MRC-F.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4546

1910.106 F06

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 23, 2019
Penalty
Initial $3,864 · Current $2,226 Reduced
29 CFR 1910.106(f)(6): "No Smoking" signs were not conspicuously posted where hazard from flammable liquid vapors is normally present.    a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that signs to prohibit smoking were not posted.  The employer designated smoking area was within approximately 58 inches from the flammable storage area, which contained two 55-gallon metal drums of #1 Network Pro 100 solvent and a 5-gallon plastic container of MRC-F.
Recent events (2)
  • — I (S) $2225.75
  • — Z (S) $3864

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 23, 2019
Abate by
Feb 4, 2019
Penalty
Initial $3,789 · Current $2,226 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedures, employee training, and periodic inspections, to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4).      a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not establish a LOTO program with inspections, procedures, and training, prior to allowing employees to clean and do repairs on presses and covers that have multiple sources of energy.
Recent events (2)
  • — I (S) $2225.75
  • — Z (S) $3789

1910.178 L01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 23, 2019
Abate by
Feb 19, 2019
Penalty
Initial $2,273 · Current $1,150 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to struck-by hazards in that the employer did not train, evaluate and certify each employee to operate the walk behind pallet stacker pallet jack, when employees were required to move and store palletized materials.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2273

1910.219 F03

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Jan 23, 2019
Abate by
Feb 19, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed:   a) Production Area - Mitsubishi Offset Press: On or before July 24, 2018, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not guard the chains and sprockets for the printer press.  b) Production Area - Akiyama Press: On or before July 24, 2018, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not guard the chain and sprockets for the printer press.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3031

1910.106 D03 II

Other-than-serious 1 instance 10 exposed
Issued
Jan 23, 2019
Abate by
Feb 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(3)(ii): Flammable and combustible liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable-Keep Fire Away":   a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that the employer did not identify the flammable material storage building with appropriate signage indicating "Flammable-Keep Fire Away", when allowing employees to smoke with in in the immediate area of the storage building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.106 E09 III

Other-than-serious 1 instance 3 exposed
Issued
Jan 23, 2019
Abate by
Feb 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(9)(iii): Combustible waste materials and residues were not stored in covered metal receptacles and disposed of daily:  a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that the containers containing solvent soaked rags were not equipped with self-closing covers and disposed of on a daily basis.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 10 exposed
Issued
Jan 23, 2019
Abate by
Mar 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:      a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire, struck-by, caught-in hazards in that the employer did not certify that a hazard assessment had been performed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 2 instances 4 exposed
Issued
Jan 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    a) Production Area - Near Pigment Storage: On or before July 24, 2018, and at times prior, the employer exposed employees to shock hazards in that the all junction boxes did not have a cover or faceplate.  b) Production Area - Near Heidelberg Presses: On or before July 24, 2018, and at times prior, the employer exposed employees to shock hazards in that the all junction boxes did not have a cover or faceplate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Jan 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were being used as a permanent source for wiring.   a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to shock hazards in that an extension cord was used to power the Polar Mohr model 115 EM Industrial counter.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Jan 23, 2019
Abate by
Mar 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will  be met:    a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to chemical hazards in that the employer did not establish a written hazard communication program with up-to-date and readily available SDS, a chemical list, and training when using chemical products such as but not limited to #1 Network Pro 100 solvent and MRC-F.