BREMEN, GA —
OSHA Inspection: GATEWAY PRINTING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GATEWAY PRINTING COMPANY, INC. in 925 PACIFIC AVE, BREMEN, GA 30110 (NAICS 323111). OSHA activity number 343321626.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GATEWAY PRINTING COMPANY, INC.
- Site address
- 925 PACIFIC AVE
- City
- BREMEN
- State
- GA
- ZIP
- 30110
- Mailing
- 925 PACIFIC AVE, BREMEN, GA 30110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 18
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.106 D05 VI A
- Issued
- Jan 23, 2019
- Abate by
- Feb 19, 2019
- Penalty
- Initial $4,546 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.106(d)(5)(vi)(a): When the storage building was located 50 feet (15.2 m) or less from a building or line of adjoining property that could be built upon, the exposing wall was not a blank wall having a fire-resistance rating of at least 2 hours: a) Outside Flammable Storage Building: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that the walls of the storage building provided did not have a fire-resistance rating of at least 2 hours when storing two 55 gallon drums of #1 Network Pro 100 solvent and a 5 gallon plastic container of MRC-F.
Recent events (2)
- — I (S) $3150
- — Z (S) $4546
1910.106 F06
- Issued
- Jan 23, 2019
- Penalty
- Initial $3,864 · Current $2,226 Reduced
General-duty citation text
29 CFR 1910.106(f)(6): "No Smoking" signs were not conspicuously posted where hazard from flammable liquid vapors is normally present. a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that signs to prohibit smoking were not posted. The employer designated smoking area was within approximately 58 inches from the flammable storage area, which contained two 55-gallon metal drums of #1 Network Pro 100 solvent and a 5-gallon plastic container of MRC-F.
Recent events (2)
- — I (S) $2225.75
- — Z (S) $3864
1910.147 C01
- Issued
- Jan 23, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $3,789 · Current $2,226 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedures, employee training, and periodic inspections, to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4). a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not establish a LOTO program with inspections, procedures, and training, prior to allowing employees to clean and do repairs on presses and covers that have multiple sources of energy.
Recent events (2)
- — I (S) $2225.75
- — Z (S) $3789
1910.178 L01 I
- Issued
- Jan 23, 2019
- Abate by
- Feb 19, 2019
- Penalty
- Initial $2,273 · Current $1,150 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to struck-by hazards in that the employer did not train, evaluate and certify each employee to operate the walk behind pallet stacker pallet jack, when employees were required to move and store palletized materials.
Recent events (2)
- — I (S) $1150
- — Z (S) $2273
1910.219 F03
- Issued
- Jan 23, 2019
- Abate by
- Feb 19, 2019
- Penalty
- Initial $3,031 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed: a) Production Area - Mitsubishi Offset Press: On or before July 24, 2018, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not guard the chains and sprockets for the printer press. b) Production Area - Akiyama Press: On or before July 24, 2018, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not guard the chain and sprockets for the printer press.
Recent events (2)
- — I (S) $0
- — Z (S) $3031
1910.106 D03 II
- Issued
- Jan 23, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Flammable and combustible liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable-Keep Fire Away": a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that the employer did not identify the flammable material storage building with appropriate signage indicating "Flammable-Keep Fire Away", when allowing employees to smoke with in in the immediate area of the storage building.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.106 E09 III
- Issued
- Jan 23, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste materials and residues were not stored in covered metal receptacles and disposed of daily: a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire hazards in that the containers containing solvent soaked rags were not equipped with self-closing covers and disposed of on a daily basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- Jan 23, 2019
- Abate by
- Mar 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to fire, struck-by, caught-in hazards in that the employer did not certify that a hazard assessment had been performed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Jan 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Production Area - Near Pigment Storage: On or before July 24, 2018, and at times prior, the employer exposed employees to shock hazards in that the all junction boxes did not have a cover or faceplate. b) Production Area - Near Heidelberg Presses: On or before July 24, 2018, and at times prior, the employer exposed employees to shock hazards in that the all junction boxes did not have a cover or faceplate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jan 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were being used as a permanent source for wiring. a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to shock hazards in that an extension cord was used to power the Polar Mohr model 115 EM Industrial counter.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Jan 23, 2019
- Abate by
- Mar 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Production Area: On or before July 24, 2018, and at times prior, the employer exposed employees to chemical hazards in that the employer did not establish a written hazard communication program with up-to-date and readily available SDS, a chemical list, and training when using chemical products such as but not limited to #1 Network Pro 100 solvent and MRC-F.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323111)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343321626.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.