Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEDWELL & SON ENTERPRISE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LEDWELL & SON ENTERPRISE INC. in 3300 WACO STREET, TEXARKANA, TX 75501 (NAICS 336212). OSHA activity number 343327227.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ledwell & SON Enterprise INC. — free Get an email when a new federal OSHA severe-injury report for Ledwell & SON Enterprise INC. is published. One employer, no account, unsubscribe in one click.
Site address
3300 WACO STREET
City
TEXARKANA
State
TX
ZIP
75501
Mailing
3300 WACO STREET, TEXARKANA, TX 75501
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
420
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Other-than-serious 5 instances 2 exposed
Issued
Sep 25, 2018
Abate by
May 17, 2019
Penalty
Initial $12,934 · Current $7,250 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    In the alternative      29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      On or before July 10, 2018 employees servicing press brakes were exposed to amputations hazards when hazardous energy was not controlled.     a) Accurpress- Model # 740020 Ser. # 11073     b)Cincinnati Incorporated-Model# UNK Ser. # 54520     c) Cincinnati Incorporated-Model # UNK Ser. # 47804     d) Hydr-Tool-Model #1200-12R Ser. # 5862631     e) Cincinnati Incorporated-Model # Ser. # 48628
Recent events (3)
  • — F (O) $7250
  • — C (S) $12934
  • — Z (S) $12934

1910.212 A01

Other-than-serious 5 instances 8 exposed
Issued
Sep 25, 2018
Abate by
Nov 30, 2019
Penalty
Initial $12,934 · Current $7,250 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     On or before July 10, 2018 employees in the fabrication department were exposed amputation hazards when operating a hydraulic brake press with no guarding.     b)Cincinnati Incorporated-Model# UNK Ser. # 54520     c) Cincinnati Incorporated-Model # UNK Ser. # 47804     d) Hydr-Tool-Model #1200-12R Ser. # 5862631     e) Cincinnati Incorporated-Model # Ser. # 48628
Recent events (3)
  • — F (O) $7250
  • — C (S) $12934
  • — Z (S) $12934

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343327227.