TEXARKANA, TX —
OSHA Inspection: LEDWELL & SON ENTERPRISE INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LEDWELL & SON ENTERPRISE INC. in 3300 WACO STREET, TEXARKANA, TX 75501 (NAICS 336212). OSHA activity number 343327227.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEDWELL & SON ENTERPRISE INC.
- Site address
- 3300 WACO STREET
- City
- TEXARKANA
- State
- TX
- ZIP
- 75501
- Mailing
- 3300 WACO STREET, TEXARKANA, TX 75501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 420
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Sep 25, 2018
- Abate by
- May 17, 2019
- Penalty
- Initial $12,934 · Current $7,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: In the alternative 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or before July 10, 2018 employees servicing press brakes were exposed to amputations hazards when hazardous energy was not controlled. a) Accurpress- Model # 740020 Ser. # 11073 b)Cincinnati Incorporated-Model# UNK Ser. # 54520 c) Cincinnati Incorporated-Model # UNK Ser. # 47804 d) Hydr-Tool-Model #1200-12R Ser. # 5862631 e) Cincinnati Incorporated-Model # Ser. # 48628
Recent events (3)
- — F (O) $7250
- — C (S) $12934
- — Z (S) $12934
1910.212 A01
- Issued
- Sep 25, 2018
- Abate by
- Nov 30, 2019
- Penalty
- Initial $12,934 · Current $7,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or before July 10, 2018 employees in the fabrication department were exposed amputation hazards when operating a hydraulic brake press with no guarding. b)Cincinnati Incorporated-Model# UNK Ser. # 54520 c) Cincinnati Incorporated-Model # UNK Ser. # 47804 d) Hydr-Tool-Model #1200-12R Ser. # 5862631 e) Cincinnati Incorporated-Model # Ser. # 48628
Recent events (3)
- — F (O) $7250
- — C (S) $12934
- — Z (S) $12934
More inspections in this industry (NAICS 336212)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343327227.