LEOMINSTER, MA —
OSHA Inspection: SEDDON INTERIORS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SEDDON INTERIORS, LLC in 38 COMMERCIAL ROAD, LEOMINSTER, MA 01453 (NAICS 238130). OSHA activity number 343330155.
Where did this inspection happen?
- Establishment
- SEDDON INTERIORS, LLC
- Site address
- 38 COMMERCIAL ROAD
- City
- LEOMINSTER
- State
- MA
- ZIP
- 01453
- Mailing
- 3012 HILLCREST LANE, EXPORT, PA 15632
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee on a walking working surface with an unprotected edge which is 6 feet or more above a lower level, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems. (a) On the roof of the restaurant renovation project at 38 Commercial Road, Leominster, MA 01453, on 7/19/2018 and at times earlier employees were engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) On the roof of the restaurant renovation project at 38 Commercial Road, Leominster, MA 01453, on 7/19/2018 and at times earlier employees were exposed to fall hazards up to 17 feet and the employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a) On the roof of the restaurant renovation project at 38 Commercial Road, Leominster, MA 01453, on 7/19/2018 and at times earlier employees were exposed to fall hazards up to 17 feet and the employer had not verified compliance with paragraph (a) of this section by preparing a written training certification record which included the name or other identity of the employee trained, the date of the training, and the signature of the person who conducted the training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) On the roof of the restaurant renovation project at 38 Commercial Road, Leominster, MA 01453, on 7/19/2018 a portable ladder was used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343330155.