STARKVILLE, MS —
OSHA Inspection: FELIX LAGOS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FELIX LAGOS in 103 EUDORA WELTY DRIVE BUILDING O, STARKVILLE, MS 39759 (NAICS 238160). OSHA activity number 343330668.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FELIX LAGOS
- Site address
- 103 EUDORA WELTY DRIVE BUILDING O
- City
- STARKVILLE
- State
- MS
- ZIP
- 39759
- Mailing
- 133 BLUEBIRD AVENUE, RICHLAND, MS 39218
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Sep 5, 2018
- Penalty
- Initial $1,663 · Current $1,663
General-duty citation text
29 CFR 1926.102(a)(1): 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical agents. (a) Building 0 - On or about June 20, 2018 employee used pneumatic nail gun to install roofing ridge cap without eye protection.
Recent events (1)
- — Z (S) $1663
1926.501 B11
- Issued
- Sep 5, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. (a) Building 0 - On or about July 20, 2018 employees installing ridge caps on a 6/12 roof did not use fall protection.
Recent events (1)
- — Z (S) $3880
More inspections in this industry (NAICS 238160)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343330668.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.