CHICAGO, IL —
OSHA Inspection: CROWN ENERGY SERVICES, INC. DBA ABLE ENGINEERING SERVICES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CROWN ENERGY SERVICES, INC. DBA ABLE ENGINEERING SERVICES, INC. in 300 S. WACKER, CHICAGO, IL 60606 (NAICS 541330). OSHA activity number 343335642.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 300 S. WACKER
- City
- CHICAGO
- State
- IL
- ZIP
- 60606
- Mailing
- 150 N WACKER SUITE 1800, CHICAGO, IL 60606
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541330
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 F03 II C
- Issued
- Jan 8, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $12,934 · Current $12,934
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(C): When more than one crew, craft, department, etc. is involved, assignment of overall job-associated lockout or tagout control responsibility will be made to an authorized employee designated to coordinate affected work forces and ensure continuity of protection: (a) On or about July 20, 2018, the employer did not assign responsibility to a designated, authorized employee to coordinate the work under group lockout of the employees working on and around the ER-3 Air Return Fan. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OFCORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $12934
- — C (S) $12934
- — Z (S) $12934
1910.147 C04 II B
- Issued
- Jan 8, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $71,137 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following specific procedural st0pes for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about July 20, 2018, the employer had not documented equipment specific procedural steps for isolating electrical and kinetic energy for the rotating belts and pulleys on the ER-3 Air Return Fan and Air Supply Fan. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records
Recent events (3)
- — F (S) $0
- — C (R) $71137
- — Z (R) $71137
1910.219 C02 I
- Issued
- Jan 8, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $10,163 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) 36th Floor- On or about July 20, 2018, the employer failed to ensure that horizontal rotating shafts, such as the shafts on the ER-3 Air Return Fan, ER-7 Air Return Fan, ER-8 Air Return Fan, and S-7 Air Supply Fan were guarded. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $10163
- — Z (S) $10163
1910.219 D01
- Issued
- Jan 8, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) 36th Floor- On or about July 20, 2018, the employer failed to ensure that all pulleys within seven or less feet from the ground or working platform on the ER-3 Air Return Fan, ER-7 Air Return Fan, ER-8 Air Return Fan, and S-7 Air Supply Fan were provided with a guard on all exposed sides. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Jan 8, 2019
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) 36th Floor- On or about July 20, 2018, the employer failed to ensure that all inclined belts within seven or less feet from the ground or working platform on the ER-3 Air Return Fan, ER-7 Air Return Fan, ER-8 Air Return Fan, and S-7 Air Supply Fan were provided with a guard on all exposed sides. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Crown Energy Services, INC. DBA Able Engineering Services, INC.
View Crown Energy Services, INC. DBA Able Engineering Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 541330)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343335642.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.