Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED STATES STEEL CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of UNITED STATES STEEL CORPORATION in [2600-2900] EDWARDSVILLE RD GRANITE CITY WORKS - IRONWORKS, GRANITE CITY, IL 62040 (NAICS 331111). OSHA activity number 343337259.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Steel Corporation — free Get an email when a new federal OSHA severe-injury report for United States Steel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
[2600-2900] EDWARDSVILLE RD GRANITE CITY WORKS - IRONWORKS
City
GRANITE CITY
State
IL
ZIP
62040
Mailing
1951 STATE ST, GRANITE CITY, IL 62040
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331111
Employees
1506
Ownership type
A

3 citations on file for this inspection.

1910.1000 A02

Serious Gravity 10 2 instances 8 exposed
Issued
Jan 25, 2019
Abate by
Mar 14, 2019
Penalty
Initial $13,260 · Current $12,000 Reduced

Hazardous substances 0560C730

29 CFR 1910.1000(a)(2): Employees were exposed to an airborne concentration of carbon monoxide listed in Table Z-1 in excess of the 8-hour Time Weighted Average (TWA) concentration of 50 parts per million (ppm):    At the Ironworks campus, a subcontractor constructed a temporary work structure near Flare Stack #1s condensate drain discharge.  The area was known to have the potential for elevated levels of toxic gases, including carbon monoxide.     a) On or about July 26th, 2018, an employee of Thermal Solutions, Inc. was exposed to a carbon monoxide concentration of approximately 1207.5 ppm while working in close proximity to Flare Stack #1.  The exposure occurred over a 60 minute period, which equates to an 8-hour TWA of approximately 150.9 ppm. The carbon monoxide level was derived from blood carboxyhemoglobin levels.    b) On or about July 26th, 2018, an employee of Thermal Solutions, Inc. was exposed to a carbon monoxide concentration of approximately 938.2 ppm while working in close proximity to Flare Stack #1.  The exposure occurred over a 60 minute period, which equates to an 8-hour TWA of approximately 117.3 ppm. The carbon monoxide level was derived from blood carboxyhemoglobin levels.
Recent events (3)
  • — F (S) $12000
  • — C (S) $13260
  • — Z (S) $13260

1910.1000 E

Serious Gravity 10 1 instance 8 exposed
Issued
Jan 25, 2019
Abate by
Mar 14, 2019
Penalty
Initial $0 · Current $12,000

Hazardous substances 0560C730

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):       At the Ironworks campus, a subcontractor constructed a temporary work structure near Flare Stack #1s condensate drain discharge.  The area was known to have the potential for elevated levels of toxic gases, including carbon monoxide.       a) On or about July 26th, 2018, an employee of Thermal Solutions, Inc. was exposed to a carbon monoxide concentration of approximately 1207.5 ppm while working in close proximity to Flare Stack #1.  The exposure occurred over a 60 minute period, which equates to an 8-hour TWA of approximately 150.9 ppm. The carbon monoxide level was derived from blood carboxyhemoglobin levels.  b) On or about July 26th, 2018, an employee of Thermal Solutions, Inc. was exposed to a carbon monoxide concentration of approximately 938.2 ppm while working in close proximity to Flare Stack #1.  The exposure occurred over a 60 minute period, which equates to an 8-hour TWA of approximately 117.3 ppm. The carbon monoxide level was derived from blood carboxyhemoglobin levels
Recent events (3)
  • — F (S) $12000
  • — C (S) $0
  • — Z (S) $0

1910.1200 E02 II

Deleted Serious Gravity 10 4 instances 25 exposed
Issued
Jan 25, 2019
Abate by
Feb 21, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.1200(e)(2)(ii): The employer's hazard communication program did not include methods the employer will use to inform the other employer(s) of any precautionary measures that need to be taken to protect employees during the workplace's normal operations and in foreseeable emergencies:    The employer did not ensure that the written hazard communication program included the methods that the host employer will use to inform other employers of any precautionary measures that need to be taken to protect employees during the condensation drainage process that occurs at the flare stacks and drip legs.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260