AKRON, OH —
OSHA Inspection: AKRON POLYMER PRODUCT, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AKRON POLYMER PRODUCT, INC. in 571 KENNEDY RD., AKRON, OH 44305 (NAICS 326199). OSHA activity number 343342093.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AKRON POLYMER PRODUCT, INC.
- Site address
- 571 KENNEDY RD.
- City
- AKRON
- State
- OH
- ZIP
- 44305
- Mailing
- 571 KENNEDY RD., AKRON, OH 44305
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 85
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Oct 4, 2018
- Abate by
- Oct 25, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about July 2, 2018, employees were exposed to machine hazards associated with moving parts, in-going nip points, and thermal hazards during a maintenance servicing task. The 129-132 dedicated plastic bender machine in the lab had a part presence sensor that was not operating properly. An employee conducting the maintenance service task did not lockout the electric and pneumatic energy sources. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect and the pneumatic valve [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards. prepare for shutdown [(d)(1)]; - ensure authorized employee has knowledge of the type, magnitude, the hazard, and the method or means to control the energy; shutdown the machine or equipment [(d)(2)]; machine isolation [(d)(3)]; physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s); LOTO device application [(d)(4)]; affix a lockout or tagout device to each energy isolating device; dissipation of residual energy [(d)(5)(i)]; relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; verification of isolation [(d)(6)]; verify that isolation and deenergization of the machine or equipment has been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343342093.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.