POST FALLS, ID —
OSHA Inspection: YOUNG CONSTRUCTION GROUP OF IDAHO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of YOUNG CONSTRUCTION GROUP OF IDAHO, INC. in 1916 CHARLEVILLE, POST FALLS, ID 83854 (NAICS 236220). OSHA activity number 343344115.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YOUNG CONSTRUCTION GROUP OF IDAHO, INC.
- Site address
- 1916 CHARLEVILLE
- City
- POST FALLS
- State
- ID
- ZIP
- 83854
- Mailing
- PO BOX 3701, COEUR D ALENE, ID 83816
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 25
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.760 A01
- Issued
- Oct 29, 2018
- Abate by
- Nov 26, 2018
- Penalty
- Initial $5,174 · Current $0 Reduced
General-duty citation text
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet* (4.6m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems: (a) Real Life Ministries Field House: On or about July 26, 2018, and at times prior thereto, the controlling contractor Young Construction Group of Idaho, Inc. did not ensure that its sub-contracted employer B.F. Builders, Inc. protected its employees with a means of fall protection while installing the OptiLiner Banded Liner system, which exposed them to the hazard of falling approximately 30 feet ground to eave. Note: Abatement Certification and Documentation ARE required.
Recent events (2)
- — I (S) $0
- — Z (S) $5174
More inspections at Young Construction Group of Idaho, INC.
View Young Construction Group of Idaho, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343344115.