SPRINGBORO, OH —
OSHA Inspection: VISINTINE CONSTRUCTION SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VISINTINE CONSTRUCTION SERVICES, LLC in 650 WEST CENTRAL AVE., SPRINGBORO, OH 45066 (NAICS 238310). OSHA activity number 343366522.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VISINTINE CONSTRUCTION SERVICES, LLC
- Site address
- 650 WEST CENTRAL AVE.
- City
- SPRINGBORO
- State
- OH
- ZIP
- 45066
- Mailing
- 6318 WATKINS RD. SW, PATASKALA, OH 43062
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C01
- Issued
- Sep 21, 2018
- Abate by
- Sep 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means: Located along the exterior area of the structure employees were observed working from a self-supported tubular welded frame scaffolding system with a 3 foot wide minimum base erected to a height in excess of 19 feet without the scaffolding system being secured to the structure or equivalent.
Recent events (1)
- — Z (S) $3880
1926.452 C02
- Issued
- Sep 21, 2018
- Abate by
- Sep 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. Located along the exterior area of the structure employees were observed working from a self-supported tubular welded frame scaffolding system which was not completely protected by cross bracing or equivalent in that none of the interior sides of the frames adjacent to the structure had cross bracing installed.
Recent events (1)
- — Z (S) $0
1926.451 F07
- Issued
- Sep 21, 2018
- Abate by
- Sep 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. Located along the exterior area of the structure the self-supported tubular welded frame scaffolding system was not erected or altered under the supervision of a competent person qualified in scaffold erection, in that cross bracing was not completely utilized, the 4 to 1 base to height was exceeded without securing the scaffold to the structure or equivalent and standard guardrails or personal fall arrest systems were not completely erected or utilized.
Recent events (1)
- — Z (S) $3880
1926.451 G01
- Issued
- Sep 21, 2018
- Abate by
- Sep 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Located along the exterior area of the structure employees were observed working from a self-supported tubular welded frame scaffolding system which was not protected by standard guardrails or personal fall arrest systems in use, exposing employees to fall potentials in excess of 13 feet.
Recent events (1)
- — Z (S) $3880
More inspections in this industry (NAICS 238310)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343366522.