Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLLEGIATE BUILDERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLLEGIATE BUILDERS, INC. in 1412 UNION ROAD, WEST SENECA, NY 14224 (NAICS 238160). OSHA activity number 343371522.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Collegiate Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Collegiate Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1412 UNION ROAD
City
WEST SENECA
State
NY
ZIP
14224
Mailing
2901 SOUTH PARK AVENUE, BUFFALO, NY 14218
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.451 F06

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Sep 11, 2018
Penalty
Initial $1,663 · Current $0 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  a) On or about 7/30/18 at a roof project located at 1412 Union Road, West Seneca, New York; employees removing shingles from the roof of a two story building were working from a roof jack scaffold with the support bracket and platform approximately 1 foot away from the electric service cable. Minimum clearance for 300 volts or less is 3 feet.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $1663

1926.501 B11

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 11, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) On or about 7/30/18 at a roof project located at 1412 Union Road, West Seneca, New York; employees were replacing shingles on the roof of a two story building. The roof had a 9 in 12 pitch and an eave height of approximately 12 feet. There was no fall protection in use.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2217
  • — Z (S) $2217

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343371522.