VANCOUVER, WA —
OSHA Inspection: FISH AND WILDLIFE SERVICE, COLUMBIA RIVER FISH AND WILDLIFE CONSERVATION OFFICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FISH AND WILDLIFE SERVICE, COLUMBIA RIVER FISH AND WILDLIFE CONSERVATION OFFICE in 1211 SE CARDINAL CT., STE 100, VANCOUVER, WA 98683 (NAICS 924120). OSHA activity number 343371936.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 1211 SE CARDINAL CT., STE 100
- City
- VANCOUVER
- State
- WA
- ZIP
- 98683
- Mailing
- 1211 SE CARDINAL CT., STE 100, VANCOUVER, WA 98683
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 45
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.145 C02 I
- Issued
- Aug 30, 2018
- Abate by
- Sep 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices: a) Warehouse Soldering Station; Caution signs were not posted to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder. This exposes employees to potential lead ingestion hazards.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Aug 30, 2018
- Abate by
- Sep 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Room 119, A Holmes heater was plugged into a surge protector (relocatable power tap). The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not heaters or appliances. This exposes employees to possible electrical fire hazards.
Recent events (1)
- — Z (S) $0
1910.157 C01
- Issued
- Aug 30, 2018
- Abate by
- Sep 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Warehouse; A fire extinguisher was sitting on the floor next to the ice machine.
Recent events (1)
- — Z (O) $0
1910.1200 G01
- Issued
- Aug 30, 2018
- Abate by
- Sep 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a) Warehouse Soldering Station; The employer did not have a safety data sheet for the Weller solder Alphafry rosin core made in Mexico and the SPC Technology desoldering braid. b) Fish Cutting Room and Laboratory; The employer did not have a safety data sheet for Bleach.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 924120)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343371936.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.