INEZ, TX —
OSHA Inspection: VICTORIA PRECISION PRODUCTS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of VICTORIA PRECISION PRODUCTS, INC. in 1511 GARCITAS CREEK RD, INEZ, TX 77968 (NAICS 327390). OSHA activity number 343372140.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VICTORIA PRECISION PRODUCTS, INC.
- Site address
- 1511 GARCITAS CREEK RD
- City
- INEZ
- State
- TX
- ZIP
- 77968
- Mailing
- PO BOX 3902, VICTORIA, TX 77903
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C01
- Issued
- Dec 4, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $2,956 · Current $2,956
05779010901390159050
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: At this precast concrete shop, the employer had not established or implemented a respiratory protection program when employees were required to wear tight-fitting respirators when using the hazardous chemicals and materials for mixing, spraying, painting, sanding, grinding structural metal and pouring concrete products. An effective respiratory protection program would include, but not limited to: a. Procedures for selecting respirators for use in the work place; b. Medical evaluation of employees required to wear respirators; c. Valid fit testing procedures for each type of tight-fitting respirators; d. Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding and maintaining respirators, and; e. Training of employees in the proper use of respirators.
Recent events (1)
- — Z (S) $2956
1910.134 D01 I
- Issued
- Dec 4, 2018
- Abate by
- Dec 21, 2018
- Penalty
- Initial $0 · Current $0
05779010901390159050
General-duty citation text
29 CFR 1910.134(d)(1)(i): The employer did not select and provide appropriate respiratory protection based on the respiratory hazard(s) to which the worker(s) was exposed and workplace and user factors that affect respirator performance and reliability: At this precast concrete shop, the employer did not select and provide adequate respiratory protection for employees working with hazardous materials. Employer provided organic vapors cartridges, instead of particulate cartridges.
Recent events (1)
- — Z (S) $0
1910.179 J02
- Issued
- Dec 4, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: At this precast concrete shop, employees hoisted heavy equipment and molds with overhead cranes. The employer did not perform frequent inspections for deficiencies for the following overhead cranes: a. Overhead crane (Kranco Houston, 5 Ton) such as but not limited to rusted cables/components; and, b. Overhead crane (Proserv 10 Ton) such as but not limited to rusted cables/components.
Recent events (1)
- — Z (S) $2217
1910.179 J03
- Issued
- Dec 4, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section: At this precast concrete shop, employees hoisted heavy equipment and molds with overhead cranes. The employer did not perform periodic inspections in the past 12 months for the following overhead cranes: a. Overhead crane (Kranco Houston, 5 Ton) such as but not limited to rusted cables/components; and, b. Overhead crane (Proserv 10 Ton) such as but not limited to rusted cables/components.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Dec 4, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $518 · Current $518
0070X100
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least: On or about January 31, 2018, at this plastic mold injection plant employees used compressed oxygen and fuel gas cylinders for welding and torching, and the compressed gas cylinders were not separated when not in use. The Victoria Precision Products, Inc. was previously cited for a violation of this Occupational Safety and Health standard, which was contained in OSHA inspection number 1241729, Citation 1, Item 1, and was issued on October 4, 2017, and was affirmed as a final order on October 19, 2017, with respect to a workplace located at 1511 Garcitas Creek Road, Inez, TX 77968.
Recent events (1)
- — Z (R) $518
1910.178 L06
- Issued
- Dec 4, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): At this precast concrete shop, employees were involved in loading and unloading concrete molds, heavy equipment, concrete blocks and septic tanks products and utilized powered industrial trucks (PITs) without certification of training and evaluation from the employer.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Dec 4, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $0 · Current $0
00700577152090109015
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: At this precast concrete shop, employees were using the hazardous chemicals and materials for mixing, spraying, painting, sanding, grinding structural metal and pouring concrete products. The employer did not developed a program which would address labeling and other forms of warning on chemicals containers, Safety Data Sheets; employees information, and training on the hazards associated with chemicals used at this site. The written program must also contain the following: a. a list of all hazardous chemicals on site; b. the methods the employer will use to inform employees of the hazards associated with non-routine tasks involving chemicals, such as a spill; c. the hazards of chemicals contained in piping that is not labeled, and; d. the method the employer will use to inform other employers (contractors) of the chemicals their employees might be exposed to while performing duties at this site.
Recent events (1)
- — Z (O) $0
More inspections at Victoria Precision Products, INC.
View Victoria Precision Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343372140.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.