CINCINNATI, OH —
OSHA Inspection: DRUMM INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DRUMM INC. in 5366 ESTE AVENUE, CINCINNATI, OH 45232 (NAICS 562998). OSHA activity number 343379798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DRUMM INC.
- Site address
- 5366 ESTE AVENUE
- City
- CINCINNATI
- State
- OH
- ZIP
- 45232
- Mailing
- 5366 ESTE AVENUE, CINCINNATI, OH 45232
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562998
- Employees
- 60
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.28 B01 I
- Issued
- Oct 31, 2018
- Abate by
- Dec 19, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): (1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: a) On August 12, 2018 while welding on a storage tank 35 feet in the air, employees were exposed to fall hazards due to unprotected sides in that Guardrail systems, Safety net, Personal Fall Protection systems such as fall arrest, travel restraint or positioning systems were not used.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.67 C02 I
- Issued
- Oct 31, 2018
- Abate by
- Dec 19, 2018
- Penalty
- Initial $9,054 · Current $9,064
General-duty citation text
29 CFR 1910.67(c)(2)(i): Lift controls shall be tested each day prior to use to determine that such controls are in safe working condition. a) On or about August 11, 2018 while operating the aerial lift, 35 feet in the air lifts controls were not tested to determine its functions in that when the controls were used the controls did not allow the lift to move. b) On or about August 12, 2018 while operating the aerial lift, 35 feet in the air lifts controls were not tested to determine its functions in that when the controls were used the controls did not allow the lift to move.
Recent events (2)
- — I (S) $9064
- — Z (S) $9054
1910.67 C02 II
- Issued
- Oct 31, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(ii): Only trained persons shall operate an aerial lift. a) On or about August 12, 2018 aerial lift operators were not trained prior to being allowed to use the malfunctioning Sky Power 800AJ lift exposing them to fall hazards of 35 feet..
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.67 C02 V
- Issued
- Oct 31, 2018
- Abate by
- Nov 28, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(v): (v) A personal fall arrest or travel restraint system that meets the requirements in 29 CFR part 1910, subpart I, shall be worn and attached to the boom or basket when working from an aerial lift. a) On or about August 11, 2018 the employees were in an High Lift equipment Sky Power 800AJ aerial lift, performing work, they were not required to wear an harness and/or belt exposing them to fall hazards of 35 feet. b) On August 12, 2018 the employees were in an High Lift equipment Sky Power 800AJ aerial lift, performing work, they were not required to wear an harness and/or belt exposing them to fall hazards of 35 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.252 A02 III A
- Issued
- Oct 31, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $9,054 · Current $9,064
General-duty citation text
29 CFR 1910.252(a)(2)(iii)(A): Fire watchers shall be required whenever welding or cutting is performed in locations where other than a minor fire might develop, or any of the following conditions exist: a) On or about August 12, 2018 while welding on a storage tank, 35 feet in the air, a fire watch was not present to prevent flare ups or fires by using a fire extinguisher, exposing them to fire/burn hazards.
Recent events (2)
- — I (S) $9064
- — Z (S) $9054
1910.252 A02 IV
- Issued
- Oct 31, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(iv): Authorization. Before cutting or welding is permitted, the area shall be inspected by the individual responsible for authorizing cutting and welding operations. He shall designate precautions to be followed in granting authorization to proceed preferably in the form of a written permit. a) On or about August 12, 2018 while welding on a storage tank 35 feet in the air, an inspection of the area was not performed by a authorizing manager, in that a Hot Work permit was not filled out to designate safety precautions, exposing employees to fire/burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.252 A02 XIII B
- Issued
- Oct 31, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(xiii)(B): Designate an individual responsible for authorizing cutting and welding operations in areas not specifically designed for such processes. a) On or about August 12, 2018 while welding on a storage tank 35 feet in the air, an authoring supervisor was not designated to ensure that operations were in accordance with safety rules.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.252 A03 I
- Issued
- Oct 31, 2018
- Abate by
- Nov 20, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(3)(i): Used containers. No welding, cutting, or other hot work shall be performed on used drums, barrels, tanks or other containers until they have been cleaned so thoroughly as to make absolutely certain that there are no flammable materials present or any substances such as greases, tars, acids, or other materials which when subjected to heat, might produce flammable or toxic vapors. Any pipe lines or connections to the drum or vessel shall be disconnected or blanked. a) On or about August 12, 2018 while welding on a storage tank 35 feet in the air flammable materials l were not removed from site, exposing employees to burns/ fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $9054