Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CMS WEST SUBSIDIARY, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CMS WEST SUBSIDIARY, LLC. in 858 NEW CASTLE ROAD, BUTLER, PA 16001 (NAICS 327390). OSHA activity number 343380440.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CMS West Subsidiary, LLC. — free Get an email when a new federal OSHA severe-injury report for CMS West Subsidiary, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
858 NEW CASTLE ROAD
City
BUTLER
State
PA
ZIP
16001
Mailing
858 NEW CASTLE ROAD, BUTLER, PA 16001
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
8
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $2,772 · Current $2,772
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falling loads:  a) Main Bay South, 858 New Castle Road, Butler, PA 16001:  On or about September August 13, 2018, a periodic inspection of Crane #1 (bridge manufacturer:  Keystone Crane and Hoist, serial number 912056, 5 ton capacity) had not been conducted within the past twelve months.  The last periodic inspection of Crane #1 occurred on December 9, 2016.  b) Main Bay Center, 858 New Castle Road, Butler, PA 16001:  On or about September August 13, 2018, a periodic inspection of Crane #2 (bridge manufacturer:  Keystone Crane and Hoist, 5 ton capacity) had not been conducted within the past twelve months.  The last periodic inspection of Crane #2 occurred on December 9, 2016.  c) Main Bay North, 858 New Castle Road, Butler, PA 16001:  On or about September August 13, 2018, a periodic inspection of Crane #3 (bridge manufacturer: Dresser Industries, serial number 912056, 5 ton capacity) had not been conducted within the past twelve months.  The last periodic inspection of Crane #3 occurred on December 9, 2016.
Recent events (3)
  • — J (S) $2772
  • — C (S) $2772
  • — Z (S) $2772

1910.147 C05 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources:      a) Production area, 858 New Castle Road, Butler, PA 16001:  On or about August 8, 2018, locks or other hardware required for locking out an electrical panel breaker switch were not provided by the employer.  The procedure for locking out the Acromix Systems batching/mixing system (model number:  BR-20210, serial number SN-74565ER021605080) required the main breaker to be locked out.
Recent events (3)
  • — J (S) $3880
  • — C (S) $3880
  • — Z (S) $3880

1910.147 C06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a) Jobsite, 858 New Castle Road, Butler, PA 16001:  On or about August 8, 2018, the employer did not conduct periodic inspections of the energy control procedures at least annually to assure the procedures were being followed.
Recent events (3)
  • — J (S) $1663
  • — C (S) $1663
  • — Z (S) $1663

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1910.147(c)(7)(i)(A):  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:   a) Production area, 858 New Castle Road, Butler, PA 16001:  On or about August 8, 2018, employees required to clean a Acromix Systems batching/mixing system (model number model number: BR-20210, serial number SN-74565ER021605080) were not provided adequate training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  Employees required to clean cement from the batching/mixing system were not trained as Authorized employees under the employer's energy control program.
Recent events (3)
  • — J (S) $3880
  • — C (S) $3880
  • — Z (S) $3880

1910.147 C07 III B

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iii)(B):  Additional retraining was not conducted whenever a periodic inspection under paragraph (c)(6)of this section revealed, or whenever the employer had reason to believe that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures:  a) Jobsite, 858 New Castle Road, Butler, PA 16001:  On or about August 8, 2018, the employer did not provide additional retraining for employees when deviations from the written procedure for locking and tagging out the Acromix Systems batching/mixing system (model number:  BR-20210, serial number SN-74565ER021605080) were observed.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  a) Production area, 858 New Castle Road, Butler, PA 16001:  Observed on or about August 13, 2018, unused openings inside the electrical cabinet labeled 'MDP' were not effectively closed.  The openings were located to the right of a Square D PowerPact QD150 circuit breaker and a Square D PowerPact QD200 circuit breaker.
Recent events (3)
  • — J (S) $2217
  • — C (S) $2217
  • — Z (S) $2217

1910.147 D02

Willful Gravity 10 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $25,867 · Current $25,867
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:      a) Production area, 858 New Castle Road, Butler, PA 16001:  On or about August 8, 2018, an Acromix Systems batching/mixing system (model number:  BR-20210, serial number SN-74565ER021605080) was not turned off or shut down using the procedures established for the machine each time it was cleaned.
Recent events (3)
  • — J (W) $25867
  • — C (W) $25867
  • — Z (W) $25867

1910.147 D03

Deleted Willful Gravity 10 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3):  All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:   a) Production area, 858 New Castle Road, Butler, PA 16001:  On or about August 8, 2018, energy isolating devices were not used to control the energy to an Acromix Systems batching/mixing system (model number:  BR-20210, serial number SN-74565ER021605080) each time it was cleaned.
Recent events (3)
  • — J (W) $0
  • — C (W) $0
  • — Z (W) $0

1910.303 E01 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 27, 2018
Abate by
Oct 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(ii):  Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:  a) Production area, 858 New Castle Road, Butler, PA 16001:  Observed on or about August 13, 2018, a Square D brand I-Line panel board (cat no. 12202139280010001) that was labeled 'MDP' was not equipped with labels or markings showing the voltage, current, wattage, and other ratings as necessary.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343380440.