Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR MASON PRODUCTS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPERIOR MASON PRODUCTS LLC in 451 INDUSTRIAL LANE, BIRMINGHAM, AL 35211 (NAICS 332312). OSHA activity number 343384814.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Mason Products LLC — free Get an email when a new federal OSHA severe-injury report for Superior Mason Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
451 INDUSTRIAL LANE
City
BIRMINGHAM
State
AL
ZIP
35211
Mailing
451 INDUSTRIAL LANE, BIRMINGHAM, AL 35211
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
90
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 14, 2018
Abate by
Mar 1, 2019
Penalty
Initial $5,497 · Current $3,848 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) On or about 08/02/2018 - Production area, E-Z Lok Deck Mill, energy control procedures were not utilized by employees when cleaning the rollers on the roll forming machine (Dhalstrom 400-16, S/N 1136).
Recent events (2)
  • — I (S) $3847.9
  • — Z (S) $5497

1910.147 C06 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 14, 2018
Abate by
Mar 1, 2019
Penalty
Initial $5,497 · Current $3,848 Reduced
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    (a) On or about 08/02/2018 - Production area, periodic inspections were not conducted for all equipment such as, but not limited to, E-Z Lok Deck Mill (Dhalstrom, 400-16, S/N 1136).
Recent events (2)
  • — I (S) $3847.9
  • — Z (S) $5497

View Superior Mason Products LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343384814.