COLORADO SPRINGS, CO —
OSHA Inspection: OMAR CUEVAS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OMAR CUEVAS in 9183 PENNYCRESS DR., COLORADO SPRINGS, CO 80925 (NAICS 238130). OSHA activity number 343385894.
Where did this inspection happen?
- Establishment
- OMAR CUEVAS
- Site address
- 9183 PENNYCRESS DR.
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80925
- Mailing
- 107 UNIVERSITY DR., COLORADO SPRINGS, CO 80909
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $1663.00
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) On or about August 14, 2018, employees were exposed eye injury in that the employees did not use safety glasses while working with or near pneumatic nail guns. Abatement Note: Abatement certification is required for this item (see the enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $1663
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $2217.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) On or about August 14, 2018, employees were exposed to falls of 12 feet high and greater while framing the second floor of a house, without fall protection. Abatement Note: Abatement certification is required for this item (see the enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $2217
1926.502 I03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: (a) On or about August 14, 2018, employees were exposed to falls hazards into window wells which were covered with wood but the wood was not secured to prevent displacement. Abatement Note: Abatement certification is required for this item (see the enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (O) $0
1926.502 I04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: (a) On or about August 14, 2018, employees were exposed to falls hazards into window wells which were covered but the covers were not marked to indicate the hazard under them. Abatement Note: Abatement certification is required for this item (see the enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343385894.