ASTON, PA —
OSHA Inspection: MCGEE INDUSTRIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MCGEE INDUSTRIES, INC. in 9 CROZERVILLE RD, ASTON, PA 19014 (NAICS 325998). OSHA activity number 343397295.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCGEE INDUSTRIES, INC.
- Site address
- 9 CROZERVILLE RD
- City
- ASTON
- State
- PA
- ZIP
- 19014
- Mailing
- PO BOX 2425, ASTON, PA 19014
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 E03 IV A
- Issued
- Feb 7, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $3,789 · Current $3,789
General-duty citation text
29 CFR 1910.106(e)(3)(iv)(a): Emergency drainage systems were not provided to direct flammable liquid leakage and fire protection water to a safe location. This may require curbs, scuppers, or special drainage systems to control the spread of fire; see paragraph (b)(2)(vii)(b) of this section. a) Jobsite: 9 Crozerville Rd, Aston, PA 19014 - Employees are exposed to fire hazards due the potential for ignited flammable liquids to spread outside the solvent mixing room in the event of a fire. An emergency drainage system and/or other means capable of containing and directing the spread of a fire protection water to a safe location in the facility was not available. This condition was observed on or about August 16, 2018.
Recent events (1)
- — Z (S) $3789
1910.134 C02 II
- Issued
- Feb 7, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $3,789 · Current $3,789
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Jobsite: 9 Crozerville Rd, Aston, PA 19014 - Employees are exposed to health hazards associated with improper use and maintenance of air purifying respirators such as but not limited to pulmonary and cardiac distress. Employees voluntarily wore Sperian 2000 series half mask air purifying respirators and 3M 7500 half mask air purifying respirators without the employer establishing and implementing the elements of a written respiratory protection program. This condition was documented to occur on or about and at times prior to August 16, 2018 in the warehouse.
Recent events (1)
- — Z (S) $3789
1910.134 E01
- Issued
- Feb 7, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Jobsite: 9 Crozerville Rd, Aston, PA 19014 - Employees are exposed to health hazards associated with improper use of air purifying respirators such as but not limited to pulmonary and cardiac distress. Employees voluntarily wore Sperian 2000 series half mask air purifying respirators and 3M 7500 half mask air purifying respirators without the employer providing medical evaluations. This condition was documented to occur on or about and at times prior to August 16, 2018 in the warehouse.
Recent events (1)
- — Z (S) $0
1910.134 F01
- Issued
- Feb 7, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Jobsite: 9 Crozerville Rd, Aston, PA 19014 - Employees are exposed to health hazards associated with improper use of air purifying respirators such as but not limited to pulmonary and cardiac distress. Employees voluntarily wore Sperian 2000 series half mask air purifying respirators and 3M 7500 half mask air purifying respirators without the employer ensuring the employees could pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT). This condition was documented to occur on or about and at times prior to August 16, 2018 in the warehouse.
Recent events (1)
- — Z (S) $0
1910.307 C02 I
- Issued
- Feb 7, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $3,789 · Current $3,789
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the class of location: a) Jobsite: 9 Crozerville Rd, Aston, PA 19014 - Employees are exposed to fire hazards due to the potential for ignition of flammable vapors inside the solvent mixing room. The emergency exit sign and light fixture installed inside the solvent mixing room is not of the approved for type for Class 1 Division 2 locations. This condition was observed on or about August 16, 2018.
Recent events (1)
- — Z (S) $3789
1910.307 D
- Issued
- Feb 7, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(d): Conduits in hazardous (classified) locations were not threaded: a) Jobsite: 9 Crozerville Rd, Aston, PA 19014 - Employees are exposed to fire hazards due to the potential for ignition of flammable vapors inside the solvent mixing room. Metal clad cable was used instead of threaded conduit to feed the emergency exit sign and light fixture. This condition was observed on or about August 16, 2018.
Recent events (1)
- — Z (S) $0
More inspections at Mcgee Industries, INC.
View Mcgee Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343397295.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.