PITTSBURG, KS —
OSHA Inspection: SANDERSON PIPE CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SANDERSON PIPE CORPORATION in 1800 ATKINSON AVENUE, PITTSBURG, KS 66762 (NAICS 326122). OSHA activity number 343397519.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SANDERSON PIPE CORPORATION
- Site address
- 1800 ATKINSON AVENUE
- City
- PITTSBURG
- State
- KS
- ZIP
- 66762
- Mailing
- 1800 ATKINSON AVENUE, PITTSBURG, KS 66762
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326122
- Employees
- 176
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Dec 4, 2018
- Abate by
- Feb 21, 2020
- Penalty
- Initial $11,641 · Current $11,641
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: Employee(s) were exposed to amputation hazards. On or about August 9, 2018, an employee engaged in maintenance activities handling ingredient scale #2 located in blending facility, was exposed to amputation hazards in that specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy related to the pneumatic gate was not developed, documented and utilized.
Recent events (3)
- — F (S) $11641
- — C (S) $11641
- — Z (S) $11641
1910.147 C04 II C
- Issued
- Dec 4, 2018
- Abate by
- Feb 21, 2020
- Penalty
- Initial $11,641 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. Employee(s) were exposed to amputation hazards. On or about August 9, 2018, an employee engaged in maintenance activities handling ingredient scale #2 located in blending facility was exposed to amputation hazards in that specific procedural steps for placement, removal and transfer of lockout devices and the responsibility related to the pneumatic gate was not developed, documented and utilized.
Recent events (3)
- — F (S) $0
- — C (S) $11641
- — Z (S) $11641
1910.147 D02
- Issued
- Dec 4, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $11,641 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: Employee(s) were exposed to amputation hazards. On or about August 9, 2018, an employee engaged in maintenance activities handling ingredient scale #2 located in blending facility was exposed to amputation hazards in that valve on the air hose related to the pneumatic door was not turned off.
Recent events (3)
- — F (S) $0
- — C (S) $11641
- — Z (S) $11641
1910.147 D04 I
- Issued
- Dec 4, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $11,641 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: Employee(s) were exposed to amputation hazards. On or about August 9, 2018, an employee engaged in maintenance activities handling ingredient scale #2 located in blending facility was exposed to amputation hazards in that valve on the air hose related to the pneumatic door was not locked out.
Recent events (3)
- — F (S) $0
- — C (S) $11641
- — Z (S) $11641
More inspections at Sanderson Pipe Corporation
View Sanderson Pipe Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326122)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343397519.