Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIDENT CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRIDENT CONSTRUCTION, INC. in MEMORIAL HOSPITAL PEDIATRIC CENTER 5002 WATERS AVENUNE, SAVANNAH, GA 31401 (NAICS 238160). OSHA activity number 343398319.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trident Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Trident Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
MEMORIAL HOSPITAL PEDIATRIC CENTER 5002 WATERS AVENUNE
City
SAVANNAH
State
GA
ZIP
31401
Mailing
605 HWY 393 A3, SANTA ROSA BEACH, FL 32459
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Other-than-serious 1 instance 9 exposed
Issued
Feb 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a) On or about February 15, 2019, at the above referenced inspection site, the employer did not ensure the site was inspected frequently insomuch that a fire extinguisher was stored directly next to a propane tank used to supply fuel for the flame process of the roofing work.
Recent events (1)
  • — Z (O) $0

1926.502 D15

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee:  a) On or about February 15, 2019, at the above referenced inspection site, the employer did not provide evidence or attempt to determine whether the anchor point used by employees, who performed work at the edge of the flat roof of a commercial building, was rated to withstand the potential weight of 5,000 pounds generated during a fall event.
Recent events (1)