CINCINNATI, OH —
OSHA Inspection: WINE CELLAR INNOVATIONS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WINE CELLAR INNOVATIONS, LLC in 4575 EASTERN AVENUE, CINCINNATI, OH 45226 (NAICS 321999). OSHA activity number 343408498.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WINE CELLAR INNOVATIONS, LLC
- Site address
- 4575 EASTERN AVENUE
- City
- CINCINNATI
- State
- OH
- ZIP
- 45226
- Mailing
- 4575 EASTERN AVENUE, CINCINNATI, OH 45226
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 100
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.22 A01
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $9,054 · Current $2,264 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. On or about 8/22/2018 an employer did not properly ensure that the work place was kept clean in that combustible wood dust was located throughout the facility such as but not limited to the 1st floor next to the belt sander, the routers and saws. Wood dust had collected on electrical components located on the first floor such as but not limited to the electrical supply box for the lighting system, main shutoff for the belt sander and the junction box located next to the sprinkler drain off valve on the south wall.
Recent events (2)
- — I (S) $2263.5
- — Z (S) $9054
1910.147 C06 I
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $9,054 · Current $2,264 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about 8/22/2018 an employer did not conduct periodic inspection of the energy control procedures to ensure the procedures and requirements were being followed, such as but not limited to: the control of energy during servicing and/or maintenance of machines and equipment. Employees were not utilizing the LOTO procedures to perform maintenance or repairs such as changing a belt on a sander or removing a defective blade.
Recent events (2)
- — I (S) $2263.5
- — Z (S) $9054
1910.147 C07 I
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: a) On or about 8/22/2018 an employer did not properly train employees on the purpose and function of the energy control program, the employer did not ensure that employees had the knowledge and skills required for the safe application, usage and removal of the energy isolation procedures during repairs or maintenance such as but not limited to changing a belt on a sander or removing a defective blade.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.147 D
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a) On or about 8/22/2018 employees who performed maintenance on belt sanders, band saws, table saws, routers, etc in the facility were not required to: (1) Turn off and shut down the belt sanders, band saws, table saws, routers etc. (2) Physically locate and operate energy isolating devices in such a manner as to isolate machine or equipment from the energy source. (3) Affix lockout or tagout devices to energy isolating electrical device(s); and (4) verify that isolation and de-energization of the machine or equipment have been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.178 C02 VI A
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $9,054 · Current $2,264 Reduced
General-duty citation text
29 CFR 1910.178(c)(2)(vi)(a): Only approved power operated industrial trucks designated as EX shall be used in atmospheres in which combustible dust is or may be in suspension continuously, intermittently, or periodically under normal operating conditions, in quantities sufficient to produce explosive or ignitable mixtures, or where mechanical failure or abnormal operation of machinery or equipment might cause such mixtures to be produced. a)On or about 8/22/2018 employees operating a Yale Powered Industrial Truck fueled by Liquefied Petroleum Gas within an area that was Class II Division I due to combustible wood dust located on equipment and floors throughout the facility Wood dust had collected on electrical components located on the first floor such as but not limited to the electrical supply box for the lighting system, main shutoff for the belt sander and the junction box located next to the sprinkler drain off valve on the south wall, exposing employees to an explosion fire hazard.
Recent events (2)
- — I (S) $2263.5
- — Z (S) $9054
1910.178 L01 II
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5). a)On or about 8/22/2018 an employer did not ensure to properly train employees on operating powered industrial trucks including powered walkies.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 P04
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $7,760 · Current $3,066 Reduced
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machines shall be provided with guards at each nip point where the sanding belt runs on to a pulley. These guards shall effectively prevent the hands or fingers of the operator from coming in contact with the nip points. The unused run of the sanding belt shall be guarded against accidental contact. a)On or about 8/22/2018 an employer did not properly guard the unused portion of the Cantek belt sander nip points exposing employees to a caught in hazard.
Recent events (2)
- — I (S) $3066
- — Z (S) $7760
1910.242 B
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $7,760 · Current $3,380 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. a)On or about 8/22/2018 an employer did not properly reduce the PSI for the compressed air utilized by employees for the cleaning of themselves or equipment exposing employees to hazards associated with compressed air measured at greater than 30 PSI: Test location #1 was in the middle of the facility in building #1, the readings were reading between 60 and 80 PSI, the gauge connected to the hose was reading approx. 70 PSI. Test location #2 was located in Building #2, the readings were between 70 and 120 PSI, The gauge connected to the hose was reading 80 PSI.
Recent events (2)
- — I (S) $3380
- — Z (S) $7760
1910.303 B01
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $9,054 · Current $2,264 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations: a)On or about 8/22/2018 an employer did not provide electric equipment free from recognized hazards exposing employees to serious harm. The facilities roof was leaking in such areas as but not limited to the first floor, builder assembly area, above the dust extractors next to the south wall of the facility and the north wall ceiling next to the Beiss routers, allowing water to come in through the ceiling tiles onto the live electrical components such as main circuit breakers, power sources, junction boxes and control panels exposing employees to electrocution hazards.
Recent events (2)
- — I (S) $2263.5
- — Z (S) $9054
1910.303 F02
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. a)Employer did not properly mark circuit breakers located in the maintenance building to identify each electrical component for its intended purpose.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a)On or about 8/22/2018 employees were exposed to electrical shock due to live wires of greater than 50 volts hanging from different electrical components such as, but not limited to junction boxes, outlets, and open supply cabinets located throughout the facility in such locations as the electrical supply box for the lighting system, main shutoff for the belt sander and the junction box located next to the sprinkler drain off valve on the south wall.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 II
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards shall be so arranged and of such strength as to prevent such damage. a)On or about 8/22/2018 an employer did properly guard the double florescent light fixtures from physical damage throughout the facility in locations such as but not limited to the battier charging/maintenance room.. Employees are exposed to hazards associated with a florescent light bulb breaking in a Class II Division I location.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) On or about 8/22/2018 employees were exposed to electrical hazards due to openings in live electrical components located throughout the facility in such areas but not limited to a circuit breaker cabinet and the 480 electric control panel located on the wall behind the blue conveyer belt located in building #3 has unused openings, exposing employees to live electrical components.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a)On or about 8/22/2018 the employer did not provide covers for the circuit breaker boxes and junction boxes in locations such as but not limited to the planers on the first floor, exposing employees to an electrocution hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Oct 19, 2018
- Abate by
- Dec 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Electrical installations. Equipment, wiring methods, and installations of equipment in hazardous (classified) locations shall be intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location. Requirements for each of these options are as follows: a) On or about 8/22/2018 an employer did not ensure that the electrical equipment, electrical wiring and installation was intrinsically safe, wiring and electrical components must be approved for Class II Division I electrical installations, due to the amount of combustible dust located in areas such as but not limited to the area of the Biesse routers and the area behind the Cantek belt sander.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Wine Cellar Innovations, LLC
View Wine Cellar Innovations, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343408498.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.