Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TARGET CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TARGET CORPORATION in 679 E DUNDEE RD,, PALATINE, IL 60074 (NAICS 452111). OSHA activity number 343411062.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Target Corporation — free Get an email when a new federal OSHA severe-injury report for Target Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
TARGET CORPORATION
Site address
679 E DUNDEE RD,
City
PALATINE
State
IL
ZIP
60074
Mailing
679 E DUNDEE RD,, PALATINE, IL 60074
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452111
Employees
150
Ownership type
A

4 citations on file for this inspection.

1910.305 G02 II

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 6, 2018
Abate by
Sep 25, 2018
Penalty
Initial $6,097 · Current $4,268 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    (a) Shipping and Receiving - On August 23, 2018, the employer failed to ensure that all flexible cords including the flexible cord at Dock Door 1, used to power the light fixture, was used in a continuous length without a splice.      In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $4268
  • — C (S) $6097
  • — Z (S) $6097

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 6, 2018
Abate by
Sep 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Shipping and Receiving - On August 23, 2018, the employer failed to ensure that flexible cords were not used as a substitute for fixed wiring. A white extension cord was used to power a fan fixture at Dock 3.  In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 6, 2018
Abate by
Sep 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Shipping and Receiving - On August 23, 2018, the employer failed to ensure that the flexible cord connected to the fan fixture at Dock 3 was connected in a manner so that strain relief was provided.    In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Sep 6, 2018
Abate by
Sep 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a) Shipping/Receiving - On August 23, 2018,  the employer did not certify that each forklift truck operator had been evaluated as required by paragraph (l), with certification records that includes the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the evaluation prior to operating an motorized pallet jack.   In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Target Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343411062.