Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FEDERAL BUREAU OF INVESTIGATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FEDERAL BUREAU OF INVESTIGATION in 3975 POLE LINE ROAD, POCATELLO, ID 83201 (NAICS 922120). OSHA activity number 343411591.

Watch Federal Bureau OF Investigation — free Get an email when a new federal OSHA severe-injury report for Federal Bureau OF Investigation is published. One employer, no account, unsubscribe in one click.
Site address
3975 POLE LINE ROAD
City
POCATELLO
State
ID
ZIP
83201
Mailing
3975 POLE LINE ROAD, POCATELLO, ID 83201
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922120
Employees
286
Ownership type
D

3 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a) On or about August 23, 2018 and at times prior thereto employees were accessing a roof 24 feet high to perform maintenance and troubleshooting and were not wearing fall protection.  NOTE-Abatement certification and documentation are required for this item.
Recent events (1)
  • — Z (S) $0

1910.30 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.30(a)(1): The employer did not provide training for each employee exposed to fall hazards and who used personal fall protection systems or is required to be trained as specified elsewhere in this subpart prior to May 17, 2017:  a) On or about August 23, 2018 and at times prior thereto employees were accessing a roof 24 feet high to perform maintenance and troubleshooting and were not trained to use fall protection or recognize the hazards.  NOTE-Abatement certification and documentation are required for this item.
Recent events (1)
  • — Z (S) $0

1926.405 J01 I

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:  (a) On or about August 23, 2018 and at times prior thereto employees were exposed to electrical hazards when internal wiring was exposed at a 110v outlet and a light switch, which had no cover plates, while power was applied.   NOTE- Abatement certification and documentation are required for this item.
Recent events (1)
  • — Z (S) $0

View FEDERAL BUREAU OF INVESTIGATION's full OSHA safety record →

PPR