FAIRWATER, WI —
OSHA Inspection: BONDUELLE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BONDUELLE in 101 KENNEDY DRIVE, FAIRWATER, WI 53931 (NAICS 311411). OSHA activity number 343412474.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BONDUELLE
- Site address
- 101 KENNEDY DRIVE
- City
- FAIRWATER
- State
- WI
- ZIP
- 53931
- Mailing
- 101 KENNEDY DRIVE, FAIRWATER, WI 53931
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311411
- Employees
- 285
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 21, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $12,934 · Current $12,934
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. On or about August 22, 2018, employees of Bonduelle were exposed to ingoing nip-points on machines that were not properly guarded. The areas where guarding was not adequate included: a. Ingoing nip-points created a by Cobb Saw Chain Return on the Cobb Cutting Deck. b. Ingoing nip-points created by moving conveyors in the Cobb Saw area on the Cobb Cutting Deck.
Recent events (2)
- — I (S) $12934
- — Z (S) $12934
1910.219 C04 I
- Issued
- Dec 21, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. On or about August 22, 2018, employees of Bonduelle working: a. In the Repack Building on the Cob Corn Wrapping Line were exposed to rotating shaft ends which had a protruding Allen Screw. b. In the Cobb Cutting Area were exposed to the rotating shaft and exposed bolts on the lower wheel section of the CCM Cutters.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C04 II
- Issued
- Dec 21, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(ii): Unused keyways shall be filled up or covered. On or about August 22, 2018, employees of Bonduelle working in the Repack Building on the Cob Corn Wrapping Line were exposed to a rotating shaft end which had a keyway that was not filled in or covered.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Dec 21, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $7,853 · Current $7,853
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. On or about August 22, 2018, Bonduelle did not ensure that electrical boxes were effectively closed to protect the wiring in boxes located: a. Above the gas alarms in the Ammonia Room. b. Above the conveyor of the west husker in the northwest portion of the outdoor corn receiving/processing area.
Recent events (2)
- — I (S) $7853
- — Z (S) $7853
1910.305 G01 IV A
- Issued
- Dec 21, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure; On or about August 22, 2018, Bonduelle was utilizing a flexible cord in place of fixed wiring to connect Panel AA to Panel C3-1 on the Electrical Mezzanine in the Repack Building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Dec 21, 2018
- Abate by
- Jan 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: Where run through holes in walls, ceilings, or floors; On or about August 22, 2018, Bonduelle was utilizing a flexible cable that had been run through a wall from the Cook Room to the Salt Pump Disconnect outside the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Bonduelle
View Bonduelle's full OSHA safety record →
More inspections in this industry (NAICS 311411)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343412474.