Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUIS RAUL OVALLE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUIS RAUL OVALLE in 21450 COUNTY RD. 12 SOUTH BUILDING 1300, FOLEY, AL 36535 (NAICS 238130). OSHA activity number 343412649.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Raul Ovalle — free Get an email when a new federal OSHA severe-injury report for Luis Raul Ovalle is published. One employer, no account, unsubscribe in one click.
Establishment
LUIS RAUL OVALLE
Site address
21450 COUNTY RD. 12 SOUTH BUILDING 1300
City
FOLEY
State
AL
ZIP
36535
Mailing
4909 WINTER COVE, MEMPHIS, TN 38138
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.502 D06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 23, 2018
Abate by
Oct 31, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself:  a) On or about August 23, 2018 at 21450 CR 12 South, Foley, Al; snaphook connected directly to lanyard: The employer did not ensure employees using personal fall arrest were properly anchored in that their rope was wrapped around a support beam/trusses and the snap hook was connected back to the rope while taking measurements and installing sheathing which exposed them to falls of over 30 feet.
Recent events (1)
  • — Z (S) $2772

1926.502 D09

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 23, 2018
Abate by
Oct 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN):  a) On or about August 23, 2018 at 21450 CR 12 South, Foley, Al; breaking strength of lanyard: The employer failed to ensure employees used proper fall protection in that they were tying their lanyard directly to the D-ring on their harness which is not allowed and may result in the lanyard breaking during a fall.
Recent events (1)
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 23, 2018
Abate by
Oct 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  a) On or about August 23, 2018 at 21450 CR 12 South, Foley, Al; free fall distance:  The employer failed to ensure employees taking measurements and installing sheathing on the roof of a residential apartment building adjusted their rope grab or used a rope grab instead of tying their lanyard with a knot to the D-ring of their harness as they moved allowing additional slack to accumulate allowing a fall of more than 6 feet.
Recent events (1)
  • — Z (S) $0

1926.1052 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 23, 2018
Penalty
Initial $1,885 · Current $1,885
29 CFR 1926.1052(b)(2): Foot traffic was not prohibited on skeleton metal stairs where permanent treads and/or landings were to be installed at a later date and the stairs were not fitted with secured temporary treads and/or landings long enough to cover the entire tread or landing area:  a) On or about August 23, 2018 at 21450 CR 12 South, Foley, Al; skeleton metal stairs without permanent treads: The employer failed to ensure the skeleton metal stairs were temporary filled in or had the permanent treads were installed before employees were allowed to use them which exposed them to the hazards associated with trip/slip/fall while going up or down the stairs.
Recent events (1)
  • — Z (S) $1885

1926.1052 C01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 23, 2018
Penalty
Initial $1,885 · Current $1,885
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) On or about August 23, 2018 at 21450 CR 12 South, Foley, Al; handrails on fixed stairs:  The employer failed to ensure handrails were installed on the metal stairs which exposed employees to fall hazards which vary up to ten feet to the concrete or wood floor.
Recent events (1)
  • — Z (S) $1885

View Luis Raul Ovalle's full OSHA safety record →