Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIAD ENGINEERING & CONTRACTING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRIAD ENGINEERING & CONTRACTING COMPANY in SHAFT 3 - EAST 140TH ST. NEORSP - SEWER POJECT, CLEVELAND, OH 44110 (NAICS 541330). OSHA activity number 343413928.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Triad Engineering & Contracting Company — free Get an email when a new federal OSHA severe-injury report for Triad Engineering & Contracting Company is published. One employer, no account, unsubscribe in one click.
Site address
SHAFT 3 - EAST 140TH ST. NEORSP - SEWER POJECT
City
CLEVELAND
State
OH
ZIP
44110
Mailing
9715 CLINTON ROAD, BROOKLYN, OH 44144
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
60
Ownership type
A

5 citations on file for this inspection.

1926.300 A

Other-than-serious 1 instance 2 exposed
Issued
Oct 16, 2018
Penalty
Initial $6,467 · Current $0 Reduced
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition:    On or about August 17, 2018, employees were installing wood blocking material between steel ribs and steel liner plates at Shaft #3 H-08 regulator shaft. Employees were using a hydraulic single acting cylinder ram (Model RC104) attached to a portable electrical Enerpac hydraulic pump unit (model PUJ1200B). Hydraulic oil was leaking from the base and pressure side of the cylinder ram because the bolt fastener was loose. The hydraulic unit on/off switch was broken and the identification label that included the capacity of the unit was missing.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6467

1926.301 A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.301(a): Unsafe hand tool(s) were issued or permitted to be used:   On or about August 17, 2018, employees at the Shaft #3 H-08 regulator shaft were using a damaged portable electrical Enerpac hydraulic pump unit (model PUJ1200B) and hydraulic single acting cylinder ram (Model RC104). The Enerpac electric start switch was broken off, the unit identification and capacity label were missing and the cylinder ram was leaking hydraulic oil.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.300 B04 III

Serious 1 instance 2 exposed
Issued
Oct 16, 2018
Abate by
Nov 30, 2018
Penalty
Initial $9,054 · Current $9,054
29 CFR 1926.300(b)(4)(iii): Special handtools for placing and removing material shall be such as to permit easy handling of material without the operator placing a hand in the danger zone. Such tools shall not be in lieu of other guarding required by this section, but can only be used to supplement protection provided:    On or about August 17, 2018, employees were exposed to a caught between hazard while using their hands to hold wood blocks in place at the Shaft #3 H-08 regulator shaft. The employees were using a portable electrical hydraulic unit with a single acting cylinder. The cylinder is used to press open the gap between the steel ribs and steel plates as the employees place the wood blocks between the steel ribs and steel plates to stiffen the structure. The employees were not using hand tools to hold the wood blocks in place.
Recent events (2)
  • — I (S) $9054
  • — Z (S) $9054

1926.305 A01

Other-than-serious 1 instance 2 exposed
Issued
Oct 16, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.305(a)(1): The manufacturer's rated capacity was not legibly marked on all jacks:    On or about August 17, 2018, employees at the Shaft #3 H-08 regulator shaft were using a portable electrical Enerpac hydraulic pump unit (model PUJ1200B) and hydraulic single acting cylinder ram (Model RC104). The identification and capacity labels were missing on the Enerpac hydraulic unit and hydraulic single acting cylinder ram.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3880

1926.305 D01 IV

Other-than-serious 1 instance 2 exposed
Issued
Oct 16, 2018
Abate by
Nov 30, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.305(d)(1)(iv): Each jack shall be thoroughly inspected at times which depend upon the service conditions:      On or about August 17, 2018, employees working at the Shaft #3 H-08 regulator shaft were using a portable electrical Enerpac hydraulic pump unit (model PUJ1200B) and cylinder ram (Model RC104) that was not thoroughly inspected upon use. The electrical start switch was broken, the cylinder ram was leaking hydraulic fluid and the manufacturers identification and capacity label was missing. The employer failed to inspect the unit [per the 1926.305(d)(1)(iv)(b) requirement] for jacks sent out of shop for special work, when sent out and when returned:
Recent events (2)
  • — I (O) $0
  • — Z (S) $3880

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343413928.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.