Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LINK MECHANICAL SERVICES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of LINK MECHANICAL SERVICES, INC. in 253 BEAVER STREET, NEW BRITAIN, CT 06051 (NAICS 811310). OSHA activity number 343414884.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Link Mechanical Services, INC. — free Get an email when a new federal OSHA severe-injury report for Link Mechanical Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
253 BEAVER STREET
City
NEW BRITAIN
State
CT
ZIP
06051
Mailing
P.O. BOX 364, NEW BRITAIN, CT 06050
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
31
Ownership type
A

4 citations on file for this inspection.

1910.101 B

Other-than-serious 1 instance 1 exposed
Issued
Nov 20, 2018
Abate by
Jan 9, 2019
Penalty
Initial $5,174 · Current $0 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6:    NEW BRITAIN FIRE DEPARTMENT HEADQUARTERS, 253 BEAVER STREET, NEW BRITAIN, CT:    On or about August 24, 2018, an employee used a rope secured around the base of the neck of a compressed gas cylinder containing nitrogen to hoist the cylinder to the roof where he was working on the HVAC system.  Once on the roof, the cylinder was placed in an upright position and was not secured to prevent it from being knocked over (CGA Pamphlet P-1-1965, Sections 3.2.4 and 3.3.8).
Recent events (2)
  • — I (O) $0
  • — Z (S) $5174

1910.102 A

Other-than-serious 1 instance 1 exposed
Issued
Nov 20, 2018
Abate by
Jan 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.102(a): The in-plant transfer, handling, storage, and utilization of acetylene in cylinders was not in accordance with Compressed Gas Association Pamphlet G-1-1966, which is incorporated by reference as specified in 29 CFR 1910.6:    NEW BRITAIN FIRE DEPARTMENT HEADQUARTERS, 253 BEAVER STREET, NEW BRITAIN, CT:    On or about and at times prior to August 24, 2018, an employee tied a rope around the neck of an acetylene cylinder to hoist it up to the roof of the building.  There was no lifting attachment on the cylinder.  Once on the roof, the cylinder was placed in an upright position and was not secured to prevent it from being knocked over (CGA Pamphlet G-1-2009, Sections 5.2 and 6.1).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 20, 2018
Abate by
Jan 9, 2019
Penalty
Initial $6,467 · Current $5,000 Reduced

Hazardous substances 06282070

29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    NEW BRITAIN FIRE DEPARTMENT HEADQUARTERS, 253 BEAVER STREET, NEW BRITAIN, CT:    On or about August 24, 2018, the employer had not developed and implemented procedures to be followed when recovering R-22 (chlorodifluoromethane) refrigerant from HVAC systems to ensure that employees would not be exposed to hazardous chemicals such as phosgene gas due to incomplete deactivation of the system and removal of all refrigerant from the system.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $6467

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Nov 20, 2018
Abate by
Jan 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  COMPANY-WIDE:  On or about and at times prior to August 24, 2018, the employer had not developed a written hazard communication program.  Hazardous chemicals which employees worked with and/or had the potential to be exposed to included, but were not limited to: refrigerants (e.g., R-22), acetylene, and compressed nitrogen gas.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343414884.