Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DANIEL DURAN AGUILAR

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DANIEL DURAN AGUILAR in 1733 SPILLWAY RD, BRANDON, MS 39047 (NAICS 238130). OSHA activity number 343417283.

Watch Daniel Duran Aguilar — free Get an email when a new federal OSHA severe-injury report for Daniel Duran Aguilar is published. One employer, no account, unsubscribe in one click.
Site address
1733 SPILLWAY RD
City
BRANDON
State
MS
ZIP
39047
Mailing
200 COLONY PARK DRIVE APT. 3201, PEARL, MS 39208
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1000.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.    (a)   Scaffold used to build stair case - On or about August 22, 2018 employees were exposed to a struck-by hazard from boards being passed overhead between employees. The employees were not wearing hard hats.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2217

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  (a)  Scaffold used to build stair case - On or about August 22, 2018 an employee was exposed to a flying object hazard while using a nail gun.  The employee was not wearing eye protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B02

Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2000.00 Reduced
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.    (a)   Scaffold used to build stair case - On or about August 22, 2018 employees were exposed to a fall hazard while working on a wooden scaffold with walkway less than 18 inches.  The scaffold walkway was constructed of single 6 inch and 8 inch wide boards and the scaffold was 12.7 feet above the ground.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

1926.451 E01

Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  (a)  Scaffold used to build stair case - On or about August 22, 2018 employees were exposed to a fall hazard while working on a wooden scaffold without a suitable access ladder. The scaffold ladders steps were not parallel, level or uniformly spaced. Also a broken ladder was used for access to the scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2000.00 Reduced
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section:    (a) Scaffold used to build stair case - On or about August 22, 2018 employees were exposed to a fall hazard while working on a scaffold 12.7 feet above the ground with no guardrails installed.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

1926.23

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.23: First aid services and provisions for medical care shall be made available by the employer for every employee covered by these regulations. Regulations prescribing specific requirements for first aid, medical attention, and emergency facilities are contained in Subpart D of this part.  (a)  On or about August 22, 2018 the employer did not provide first aid training or a first aid kit to his employees and the employer did not know the location of the nearest medical facility in case of emergency.