Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUSTAMANTE ROOFING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BUSTAMANTE ROOFING LLC in 5533 MAJESTIC DR., COLORADO SPRINGS, CO 80919 (NAICS 238160). OSHA activity number 343418356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bustamante Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Bustamante Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
5533 MAJESTIC DR.
City
COLORADO SPRINGS
State
CO
ZIP
80919
Mailing
245 SABLE BLVD APT. 9307, AURORA, CO 80011
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 19, 2018
Abate by
Oct 9, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:  (a)  On or about August 24, 2018, employees were exposed to injuries from falls, while conducting reroofing activities, without the benefit of fall protection systems being in place, on a roof in excess of six feet above the lower surface.  Abatement Note:  Abatement certification is required for this item (see the enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $2217

1926.416 E01

Other-than-serious 1 instance 3 exposed
Issued
Sep 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a)  On or about August 24, 2018, workers were exposed to shock and burn hazards from an extension cord that was use in the construction area to charge a 50 amp battery starter, which had worn and ripped insulation exposing the energized conductors inside.
Recent events (1)
  • — Z (O) $0

View Bustamante Roofing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343418356.