Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMCOR SERVICES (MESA ENERGY SYSTEMS)

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EMCOR SERVICES (MESA ENERGY SYSTEMS) in MCRD, BLDG. 569, SAN DIEGO, CA 92140 (NAICS 238220). OSHA activity number 343420345.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emcor Services (Mesa Energy Systems) — free Get an email when a new federal OSHA severe-injury report for Emcor Services (Mesa Energy Systems) is published. One employer, no account, unsubscribe in one click.
Site address
MCRD, BLDG. 569
City
SAN DIEGO
State
CA
ZIP
92140
Mailing
900 VERNON WAY, EL CAJON, CA 92020
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.150 A04

Other-than-serious 1 instance 6 exposed
Issued
Sep 14, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.150(a)(4): Firefighting equipment was not periodically inspected:   Bldg. 569, Steam Decentralization Project, MCRD:  A fire extinguisher located where gas welding is performed did not have legible tags documenting when weekly and annual inspections were conducted.
Recent events (1)
  • — Z (O) $0

1926.350 A07

Other-than-serious 1 instance 6 exposed
Issued
Sep 14, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.350(a)(7): A suitable cylinder truck, chain, or other steadying device was not used to keep compressed gas cylinder(s) from being knocked over while in use:   Bldg. 569, Steam Decentralization Project, MCRD:   An acetylene cylinder with a regulator attached was secured with a thin wire and could be knocked over.