Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TYLER FIRE EQUIPMENT SERVICE CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TYLER FIRE EQUIPMENT SERVICE CORP. in 703 ERIE STREET, ELMIRA, NY 14904 (NAICS 811198). OSHA activity number 343421434.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tyler Fire Equipment Service Corp. — free Get an email when a new federal OSHA severe-injury report for Tyler Fire Equipment Service Corp. is published. One employer, no account, unsubscribe in one click.
Site address
703 ERIE STREET
City
ELMIRA
State
NY
ZIP
14904
Mailing
703 ERIE STREET, ELMIRA, NY 14904
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
Employees
7
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 7, 2018
Abate by
Nov 28, 2018
Penalty
Initial $3,326 · Current $1,996 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazards by the load should the load slip off the hook, or the lifting device fails:      a) Service Area, on or about 7/24/18:  2-Ton Contrx  hoist, Model A41414 used to lift truck parts had a broken safety latch on the lifting hook.    Among other methods one feasible and acceptable method to correct this hazard is to:               a. Replace the broken safety clip or remove the hook from service per ASME B30.10-2014, Section 10-1-10.5; and              b. Perform frequent and periodic inspections as required by ASME B30.10-2014, Section 10.          b)  Service Area, on or about 7/24/18:  2-Ton Contrx Hoist used to lift truck parts had not been inspected on a frequent and periodic schedule.     Among other methods one feasible and acceptable method to correct this hazard is to:             a. Perform frequent and periodic inspections as required by ASME B30.16-2017, Chapter 16-2.        c)  Service Area, on or about 8/24/18:   Hydraulic transmission jacks had not been inspected on a frequent and periodic basis.  The following deficiencies were noted:        1)  The transmission jig had been modified and the employer had not performed a proof test prior to use;      2)  The leveling handle was bent.     Among other methods one feasible and acceptable method to correct these hazards is to:             a.  Have a qualified person or the manufacturer proof test the modified jack; and          b.  Replace the bent leveling handle; and          c.  Conduct frequent and periodic inspections of the jacks in accordance with ASME B30.1-2015, Chapter 1-2.
Recent events (2)
  • — I (S) $1995.6
  • — Z (S) $3326

1910.157 G02

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 7, 2018
Abate by
Nov 28, 2018
Penalty
Initial $1,663 · Current $998 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    a)  Tyler Fire Equipment Service Corp., on or about 8/24/18:  An educational program was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage firefighting, upon initial employment and at least annually thereafter.      *ABATEMENT NOTE:  By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39(a) which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (2)
  • — I (S) $997.8
  • — Z (S) $1663

1910.178 L01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 7, 2018
Abate by
Dec 13, 2018
Penalty
Initial $1,663 · Current $998 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)  Tyler Fire Equipment, LLC, on or about 8/24/18:  The employer did not ensure that each powered industrial truck operator received the required training and evaluation.
Recent events (2)
  • — I (S) $997.8
  • — Z (S) $1663

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 7, 2018
Abate by
Nov 19, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  Service Area, on or about 8/24/18:  Tradesman Miter Saw, the original flexible cord, SJT 14AWG, had been spliced and connected to a SJTW 12AWG flexible cord.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1910.305 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 7, 2018
Abate by
Nov 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a)  Service Area, on or about 8/24/18:  Tradesman Miter Saw, the original flexible cord, SJT 14AWG, had been spliced and connected to a SJTW 12AWG flexible cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 VI

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 7, 2018
Abate by
Nov 19, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
29 CFR 1910.303(b)(1)(vi): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.  Arcing effects was not taken into consideration in determining the safety of the equipment.    a)  Service Area, on or about 8/24/18:  Stertil Koni, 4-post portable lift, had the battery terminals exposed, thereby exposing employees to potential burn hazards.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1910.1200 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 7, 2018
Abate by
Nov 28, 2018
Penalty
Initial $1,663 · Current $998 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a)  Tyler Fire Equipment Service, Corp., on or about 8/24/18:  The employer did not develop a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) would be met.   Employee are exposed to materials such as but not limited to:  argon and acetylene compressed gases, parts cleaners and various oils.
Recent events (2)
  • — I (S) $997.8
  • — Z (S) $1663

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 7, 2018
Abate by
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a)  Tyler Fire Equipment Service Corp., on or about 8/24/18:  The employer did not provide information and training to employees on the hazardous chemicals being used in the work place.  Hazardous chemicals used include but are not limited to:  oils, argon and acetylene compressed gases and brake fluid.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Tyler Fire Equipment Service Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343421434.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.