ENGLEWOOD, NJ —
OSHA Inspection: GREAT WORK CONSTRUCTION CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GREAT WORK CONSTRUCTION CORP in 42 LEXINGTON COURT, ENGLEWOOD, NJ 07631 (NAICS 238170). OSHA activity number 343423679.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREAT WORK CONSTRUCTION CORP
- Site address
- 42 LEXINGTON COURT
- City
- ENGLEWOOD
- State
- NJ
- ZIP
- 07631
- Mailing
- 51 LANG ST, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.300 B01
- Issued
- Dec 17, 2018
- Penalty
- Initial $3,880 · Current $2,716 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Building/Side: Employees were exposed to an amputation hazard while using a Dewalt saw without a guard, on or about 08/28/2018.
Recent events (2)
- — I (S) $2716
- — Z (S) $3880
1926.451 B03 I
- Issued
- Dec 17, 2018
- Penalty
- Initial $3,880 · Current $2,716 Reduced
General-duty citation text
29 CFR 1926.451(b)(3)(i): The maximum distance from the face of the work for outrigger scaffold was not kept under 3 inches . a) Building Exterior: Employees exposed to a 20 foot fall hazard while working from a alum-a-pole pump jack scaffold that was 19 inches from the building. on or about 8/28/2018.
Recent events (2)
- — I (S) $2716
- — Z (S) $3880
1926.451 G01
- Issued
- Dec 17, 2018
- Penalty
- Initial $3,880 · Current $2,716 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Building Exterior: Employees exposed to a 20 foot fall hazard while working from a alum-a-pole pump jack scaffold that was not equipped with a guardrail system in place. On 8/27/2018, an employee fell approximately 20 feet from a pump jack scaffold without a guardrail system in place.
Recent events (2)
- — I (S) $2716
- — Z (S) $3880
1926.452 J02
- Issued
- Dec 17, 2018
- Penalty
- Initial $2,772 · Current $1,940 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Building Exterior: Alum-A-Pole pump jack scaffold poles were not secured at the bottom, on or about 8/27/2018.
Recent events (2)
- — I (S) $1940.4
- — Z (S) $2772
1926.501 B13
- Issued
- Dec 17, 2018
- Penalty
- Initial $3,880 · Current $2,716 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Roof: An employee were exposed to a fall hazard of approximately 20 feet while working without a personal fall arrest system or other means of fall protection from a roof, on or about 08/28/2018.
Recent events (2)
- — I (S) $2716
- — Z (S) $3880
1926.1053 B01
- Issued
- Dec 17, 2018
- Penalty
- Initial $1,663 · Current $1,164 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. Building Rear: An extension ladder used to access a rear second floor patio balcony approximately 12 feet in height did not extend three (3) feet above the landing, on or about 08/28/2018.
Recent events (2)
- — I (S) $1164.1
- — Z (S) $1663
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343423679.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.