Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE ACCENT GROUP

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of THE ACCENT GROUP in 42 LEXINGTON COURT, ENGLEWOOD, NJ 07631 (NAICS 238170). OSHA activity number 343426946.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Accent Group — free Get an email when a new federal OSHA severe-injury report for The Accent Group is published. One employer, no account, unsubscribe in one click.
Establishment
THE ACCENT GROUP
Site address
42 LEXINGTON COURT
City
ENGLEWOOD
State
NJ
ZIP
07631
Mailing
104 E. CENTRE STREET, NUTLEY, NJ 07110
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.300 B01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Dec 14, 2018
Penalty
Initial $4,268 · Current $0 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:   a) Building/Side: Employees were exposed to an amputation hazard while using a Dewalt saw without a guard, on or about 08/28/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4268

1926.451 B03 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 14, 2018
Penalty
Initial $4,268 · Current $0 Reduced
29 CFR 1926.451(b)(3)(i): The maximum distance from the face for outrigger scaffolds shall be 3 inches (8 cm);    a) Building Exterior: Employees exposed to a 20 foot fall hazard while working from a alum-a-pole pump jack scaffold that was 19 inches from the building, on or about on 8/28/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4268

1926.451 G01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 14, 2018
Penalty
Initial $8,536 · Current $0 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a) Building Exterior: Employees exposed to a 20 foot fall hazard while working from a alum-a-pole pump jack scaffold that was not equipped with a guardrail system in place. On 8/27/2018, an employee fell approximately 20 feet from a pump jack scaffold without a guardrail system in place.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8536

1926.452 J02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 14, 2018
Penalty
Initial $4,268 · Current $0 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   a) Building Exterior: Alum-A-Pole pump jack scaffold poles were not secured at the bottom, on or about 8/27/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4268

1926.501 B01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Dec 14, 2018
Penalty
Initial $4,268 · Current $0 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   a) Roof: Employees were exposed to a fall hazard of approximately 20 feet while working without a personal fall arrest system or other means of fall protection from a roof, on or about 08/28/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4268

1926.1053 B01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Dec 14, 2018
Penalty
Initial $1,829 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a. Building Rear: An extension ladder used to access a rear second floor patio balcony approximately 10 feet in height did not extend three (3) feet above the landing, on or about 08/28/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1829

View The Accent Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343426946.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.