ENGLEWOOD, NJ —
OSHA Inspection: THE ACCENT GROUP
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of THE ACCENT GROUP in 42 LEXINGTON COURT, ENGLEWOOD, NJ 07631 (NAICS 238170). OSHA activity number 343426946.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE ACCENT GROUP
- Site address
- 42 LEXINGTON COURT
- City
- ENGLEWOOD
- State
- NJ
- ZIP
- 07631
- Mailing
- 104 E. CENTRE STREET, NUTLEY, NJ 07110
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.300 B01
- Issued
- Dec 14, 2018
- Penalty
- Initial $4,268 · Current $0 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Building/Side: Employees were exposed to an amputation hazard while using a Dewalt saw without a guard, on or about 08/28/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $4268
1926.451 B03 I
- Issued
- Dec 14, 2018
- Penalty
- Initial $4,268 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(3)(i): The maximum distance from the face for outrigger scaffolds shall be 3 inches (8 cm); a) Building Exterior: Employees exposed to a 20 foot fall hazard while working from a alum-a-pole pump jack scaffold that was 19 inches from the building, on or about on 8/28/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $4268
1926.451 G01
- Issued
- Dec 14, 2018
- Penalty
- Initial $8,536 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Building Exterior: Employees exposed to a 20 foot fall hazard while working from a alum-a-pole pump jack scaffold that was not equipped with a guardrail system in place. On 8/27/2018, an employee fell approximately 20 feet from a pump jack scaffold without a guardrail system in place.
Recent events (2)
- — I (S) $0
- — Z (S) $8536
1926.452 J02
- Issued
- Dec 14, 2018
- Penalty
- Initial $4,268 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Building Exterior: Alum-A-Pole pump jack scaffold poles were not secured at the bottom, on or about 8/27/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $4268
1926.501 B01
- Issued
- Dec 14, 2018
- Penalty
- Initial $4,268 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Roof: Employees were exposed to a fall hazard of approximately 20 feet while working without a personal fall arrest system or other means of fall protection from a roof, on or about 08/28/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $4268
1926.1053 B01
- Issued
- Dec 14, 2018
- Penalty
- Initial $1,829 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. Building Rear: An extension ladder used to access a rear second floor patio balcony approximately 10 feet in height did not extend three (3) feet above the landing, on or about 08/28/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $1829
More inspections at The Accent Group