Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ULTRA CLEAN CLEANING & RESTORATION SERVICES, LLC.

Federal Agency inspection · Health discipline

On , OSHA opened a federal Agency health inspection of ULTRA CLEAN CLEANING & RESTORATION SERVICES, LLC. in 15 WEST GRANBY STREET, GRANBY, CT 06035 (NAICS 562910). OSHA activity number 343432050.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ultra Clean Cleaning & Restoration Services, LLC. — free Get an email when a new federal OSHA severe-injury report for Ultra Clean Cleaning & Restoration Services, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
15 WEST GRANBY STREET
City
GRANBY
State
CT
ZIP
06035
Mailing
203 WEST MAIN STREET, CANAAN, CT 06018
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
2
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 2 exposed
Issued
May 6, 2019
Abate by
Jun 21, 2019
Penalty
Initial $319 · Current $319
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  On or about and at times prior to May 6, 2019, the employer had not provided documentation that violations observed during an inspection at a work-site on August 29, 2018 had been corrected.
Recent events (1)
  • — Z (O) $319

1910.28 B03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 14, 2019
Abate by
Mar 4, 2019
Penalty
Initial $12,934 · Current $12,934
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee was protected from falling through any hole (including skylights) that was 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems.  15 WEST GRANBY ROAD, GRANBY, CT:  On or about August 28, 2018, employees were exposed to fall hazards while working in the attic of a house.  The employees were removing fiberglass insulation from between ceiling joists.  There was limited plywood for employees to stand or kneel on and no other fall protection provided.  An employee fell between ceiling joists and landed on the floor of the master bedroom below.  She succumbed to her injuries.
Recent events (1)
  • — Z (S) $12934

1910.303 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 14, 2019
Abate by
Mar 4, 2019
Penalty
Initial $2,217 · Current $2,217
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  15 WEST GRANBY ROAD, GRANBY, CT:  On or about August 28, 2018, the following equipment was not used in accordance with manufacturer instructions:  A)  A Leviton 698-W 15-Amp/125-Volt grounding triple outlet adaptor was used in concert with a flexible cord to energize a work lamp and a HEPA Air Scrubber.  B)  A Dri-Eaz F284 DefendAir HEPA 500 Air Scrubber equipped with a 3-prong plug was not plugged into a grounded receptacle.
Recent events (1)
  • — Z (S) $2217

1910.304 B04 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 14, 2019
Abate by
Mar 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  15 WEST GRANBY ROAD, GRANBY, CT:  On or about August 28, 2018, the employer used a Leviton 698-W 15-Amp/125-Volt grounding triple outlet adaptor to energize a yellow work lamp and a Dri-Eaz F284 DefendAir HEPA 500 Air Scrubber.  The Air Scrubber had a built-in outlet which was used to energize a Pro-Reel Fluorescent Work Light.  The total load on the adaptor was greater than 12 amps which is the maximum load specified in Table S-4.
Recent events (1)
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 3 instances 2 exposed
Issued
Jan 14, 2019
Abate by
Mar 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  15 WEST GRANBY ROAD, GRANBY, CT:  On or about August 28, 2018, employees were using electrical equipment that did not have a continuous path to ground:    A) An orange extension cord used to energize equipment being used in the attic was missing a ground pin.  B) A Leviton 3-Way Power tap with only two wires was plugged into the extension cord noted above in order to energize work lamps and an air scrubber.  The air scrubber was equipped with a 3-prong plug.  C) A Dri-Eaz F284 DefendAir HEPA 500 Air Scrubber with a 3-prong plug was plugged into an ungrounded Leviton 698-W 15-Amp/125-Volt grounding triple outlet adaptor.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343432050.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.