DUNNELLON, FL —
OSHA Inspection: AIR DISTRIBUTORS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AIR DISTRIBUTORS, INC. in 2541 W. DUNNELLON RD, DUNNELLON, FL 34433 (NAICS 333415). OSHA activity number 343437455.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR DISTRIBUTORS, INC.
- Site address
- 2541 W. DUNNELLON RD
- City
- DUNNELLON
- State
- FL
- ZIP
- 34433
- Mailing
- 2541 W. DUNNELLON RD, DUNNELLON, FL 34433
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 53
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Jan 7, 2019
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: (a) at the workplace - The point of operation of the Roto-Die Hydraulic Bender Sheet Metal Press Brake was not guarded, Model 15, S/N 394A; on or about 8/16/2018.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
1910.212 A03 III
- Issued
- Jan 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(iii): Special hand tools for placing and removing material(s) was in lieu of other guarding required by this section, not to supplement protection provided: (a) at the workplace - the employer provided pliers for employee use when fingers were less than 4 inches away from the die area when operating the Roto-Die Hydraulic Bender Sheet Metal Press Brake that was not guarded; on or about 8/28/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at AIR Distributors, INC.
View AIR Distributors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343437455.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.