AURORA, IL —
OSHA Inspection: MGO REMODELING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MGO REMODELING INC. in 103 PLYMOUTH CT, AURORA, IL 60504 (NAICS 236118). OSHA activity number 343440723.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MGO REMODELING INC.
- Site address
- 103 PLYMOUTH CT
- City
- AURORA
- State
- IL
- ZIP
- 60504
- Mailing
- 201 W GREEN MEADOWS, STREAMWOOD, IL 60107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 6, 2018
- Abate by
- Sep 28, 2018
- Penalty
- Initial $3,326 · Current $2,328 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system: On or about 05 September 2018, an employee engaged in a residential siding installation was not protected by guardrail systems, safety net systems, or a personal fall arrest systems. This exposed employees to a fall of approximately 9 feet. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2328.2
- — Z (S) $3326
1926.1053 B01
- Issued
- Sep 6, 2018
- Abate by
- Sep 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: On or about 05 September 2018, an employee engaged in a residential siding installation was provided with a metal extension ladder that was not extended at least three feet above the eave to allow for safe access to the roof. This exposed the employee to a fall of approximately 9 feet. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at MGO Remodeling INC.
View MGO Remodeling INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343440723.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.