AUGUSTA, GA —
OSHA Inspection: ARK FABRICATORS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARK FABRICATORS, INC. in 3005 INTERNATIONAL BLVD., AUGUSTA, GA 30906 (NAICS 332996). OSHA activity number 343442315.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARK FABRICATORS, INC.
- Site address
- 3005 INTERNATIONAL BLVD.
- City
- AUGUSTA
- State
- GA
- ZIP
- 30906
- Mailing
- 3501 CARMICHAEL RD. EXT, AUGUSTA, GA 30906
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 16, 2018
- Abate by
- Nov 9, 2018
- Penalty
- Initial $5,497 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On 9/5/18, at the job site located at 3005 Industrial Blvd., Augusta, Ga., the employer did not ensure employees providing service and maintenance to equipment had procedures that were developed, documented and utilized for the control of the energies on that equipment.
Recent events (2)
- — I (S) $5000
- — Z (S) $5497
1910.147 D04 II
- Issued
- Oct 16, 2018
- Abate by
- Nov 9, 2018
- Penalty
- Initial $5,497 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position. On 9/5/18, at 3005 Industrial Blvd., Augusta, Ga, authorized employees affixed locks to equipment but did not maintain control of the keys after application and instead had the keys out and available for removal.
Recent events (2)
- — I (O) $0
- — Z (S) $5497
1910.305 J01 I
- Issued
- Oct 16, 2018
- Penalty
- Initial $2,803 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact. On 9/5/18, at 3005 Industrial Blvd., Augusta, Ga., employees were exposed to electrical hazards as receptacles were not equipped with faceplates leaving live parts exposed.
Recent events (2)
- — I (S) $2000
- — Z (S) $2803
More inspections at ARK Fabricators, INC.
View ARK Fabricators, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343442315.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.