Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMERSON REMODELING INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EMERSON REMODELING INC in 130 HAASE AVE, PARAMUS, NJ 07652 (NAICS 238160). OSHA activity number 343446100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emerson Remodeling INC — free Get an email when a new federal OSHA severe-injury report for Emerson Remodeling INC is published. One employer, no account, unsubscribe in one click.
Site address
130 HAASE AVE
City
PARAMUS
State
NJ
ZIP
07652
Mailing
99 HIGHLAND AVE, EMERSON, NJ 07630
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

2 citations on file for this inspection.

1926.502 D15

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2018
Penalty
Initial $2,772 · Current $1,441 Reduced
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  a) Roof: Employee utilizing a PFAS that was anchored to a plumbing vent pipe was exposed to an approximately 14 feet fall hazard, on or about 8/29/18
Recent events (2)
  • — I (S) $1441.44
  • — Z (S) $2772

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2018
Penalty
Initial $2,772 · Current $1,441 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:   a) Roof: Employee utilizing a PFAS with it's lanyard connected approximately 6 feet below his standing position was exposed to an approximately 14 feet fall hazard, on or about 8/29/18
Recent events (2)
  • — I (S) $1441.44
  • — Z (S) $2772

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343446100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.