OSHA Inspection: LUIS FUENTES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUIS FUENTES in 7150 E GRAND AVE, DALLAS, TX 75233 (NAICS 238170). OSHA activity number 343450334.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Fuentes — free Get an email when a new federal OSHA severe-injury report for Luis Fuentes is published. One employer, no account, unsubscribe in one click.
Establishment
LUIS FUENTES
Site address
7150 E GRAND AVE
City
DALLAS
State
TX
ZIP
75233
Mailing
11710 GARDEN GROVE DR, DALLAS, TX 75253
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.403 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 12, 2018
Abate by
Oct 9, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1926.403(b)(1): Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:  (a) On September 5, 2018 employees were expose to electrocution when employer did not ensure electrical equipment is free from recognized hazard.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1926.403 I02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 12, 2018
Abate by
Oct 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:  (a) on September 5, 2018 employees were exposed to electric shock when working with tools connected to live electrical parts that were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 12, 2018
Abate by
Oct 9, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.   (a) On September 5, 2018 employees were installing siding on apartment building 18 approximately 18 feet from the lower ground level without the use of fall protection, exposing employee to a fall hazard
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 12, 2018
Abate by
Oct 9, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.   (a) On September 5, 2018 Employees were exposed to a fall of approximately 18 feet to the lower ground level by not having the ladder extended 3 feet above the landing.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

View Luis Fuentes's full OSHA safety record →