Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STEVEN'S JERSEY CITY FORD LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STEVEN'S JERSEY CITY FORD LLC in 740 ROUTE 440, JERSEY CITY, NJ 07305 (NAICS 811111). OSHA activity number 343450904.

Watch Steven'S Jersey City Ford LLC — free Get an email when a new federal OSHA severe-injury report for Steven'S Jersey City Ford LLC is published. One employer, no account, unsubscribe in one click.
Site address
740 ROUTE 440
City
JERSEY CITY
State
NJ
ZIP
07305
Mailing
740 ROUTE 440, JERSEY CITY, NJ 07305
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
22
Ownership type
A

7 citations on file for this inspection.

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    a) Shop - 740 Route 440, Jersey City, NJ    A flexible cord was not free from recognized hazards likely to cause death or serious physical harm in that the cord was missing the outer jacket which protects the live wires.    Violation observed on or about 09/07/2018.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.303 B02

Serious Gravity 5 2 instances 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Shop - 740 Route 440, Jersey City, NJ  Powerstrips were not used in accordance with instructions included in the listing and labeling in that they were daisy chained and used as permanent wiring for a refrigerator, microwave and radio.  Violation observed on or about 09/07/2018.  b) Shop - Route 440, Jersey City, NJ  Outlet and junction boxes were not used in accordance with instruction included in the listing and labeling in that they were not mounted.  Violation observed on or about 09/07/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:    a) Shop - 740 Route 440, Jersey City, NJ    Boxes used to power a welding machine were missing pre-punched knockouts exposing an employee to shock hazards.    Violation observed on or about 09/07/2018.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.303 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) Shop - 740 Route 440, Jersey City, NJ    The working space in front of and underneath the circuit breaker panel was used for storage of sheetrock.    Violation observed on or about 09/07/2018.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    a) Shop - 740 Route 440, Jersey City, NJ    A flexible cord used to power a computer was spliced and not used in a continuous length.    Violation observed on or about 09/07/2017.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.1200 E01

Serious Gravity 5 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3522.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) Facility    The employer did not develop and implement a written hazard communication program for employees exposed to hazardous chemicals such as, but not limited to, petroleum distillates found in Mercon Sp Automatic Transmission Fluid, naphtha and petroleum naphtha found in Motorcraft Fuel Injector Cleaner and carbon monoxide as a product of combustion.    Violation occurred on or about 09/07/2018.
Recent events (2)
  • — I (S) $3522
  • — Z (S) $5174

1910.1200 H01

Serious Gravity 5 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Facility          The employer did not provide information and training for employees exposed to hazardous chemicals such as, but not limited to, petroleum distillates found in Mercon Sp Automatic Transmission Fluid, naphtha and petroleum naphtha found in Motorcraft Fuel Injector Cleaner and carbon monoxide as a product of combustion.  Violation occurred on or about 09/07/2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343450904.