HANOVER TOWNSHIP, PA —
OSHA Inspection: NARDONE BROTHERS BAKING CO. INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NARDONE BROTHERS BAKING CO. INC. in 420 NEW COMMERCE BLVD, HANOVER TOWNSHIP, PA 18706 (NAICS 311812). OSHA activity number 343454088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NARDONE BROTHERS BAKING CO. INC.
- Site address
- 420 NEW COMMERCE BLVD
- City
- HANOVER TOWNSHIP
- State
- PA
- ZIP
- 18706
- Mailing
- 420 NEW COMMERCE BLVD, HANOVER TOWNSHIP, PA 18706
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 400
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.212 A03 II
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $12,934 · Current $10,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Packing line: Employees were exposed to a nip point hazard while operating the Ilipak Carrerra wrapping machine, model 2000 PC, serial #99-028, with the protective hood in the opened position, on or about September 7, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $10000
- — Z (S) $12934
1910.212 A01
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Area: A guard was not provided on the metal cutting lathe which exposed the operator to the rotating chuck and flying metal chips, on or about September 13, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C02 I
- Issued
- Dec 17, 2018
- Penalty
- Initial $6,097 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Production area, line #2: An unguarded shaft on the outfeed side of the melter exposed employees to an entanglement hazard, on or about September 13, 2018. CERTIFICATION NOT REQUIRED CORRECTED DURING INSPECTION
Recent events (2)
- — I (S) $3850
- — Z (S) $6097
1910.219 C04 I
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Line #1, Grote short blue conveyor: An unguarded rotating shaft end that had a protruding set screw exposed employees to an entanglement hazard, on or about September 13, 2018. c) Line #1, Grote short blue conveyor: An unguarded rotating shaft end that had a protruding set screw exposed employees to an entanglement hazard, on or about September 13, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 H01
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): a) Line #1, Grote orange cord conveyor: Protruding set screws on each end of the shaft on the aft side of applicator #3 exposed employees to an entanglement hazard, on or about September 13, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $6,097 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Maintenance Area: Employees were exposed to a pair of unguarded pulleys while operating a band saw, on or about September 13, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3850
- — Z (S) $6097
1910.219 E03 I
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) a) Maintenance Area: Employees were exposed to an unguarded belt while operating a band saw, on or about September 13, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $10,163 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Packing line #2: A relocatable power tap was installed and used in a manner that is prohibited by the devices listing and labeling, which exposed employees to an electric shock hazard, on or about October 19, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $7000
- — Z (S) $10163
1910.305 G01 IV A
- Issued
- Dec 17, 2018
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Bakery area: A 50-foot extension cord was improperly installed and used to provide power to a Mettler Toledo digital scale, on or about September 13, 2018. b) Packing line #1: A three-outlet extension cord was improperly installed and used to provide power to a Mettler Toledo digital scale, a label printer, and a box taper machine, on or about September 19, 2018. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Nardone Brothers Baking CO. INC.
View Nardone Brothers Baking CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343454088.