Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EOG RESOURCES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EOG RESOURCES, INC. in 1396 CR 212, SMILEY, TX 78159 (NAICS 211112). OSHA activity number 343459111.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EOG Resources, INC. — free Get an email when a new federal OSHA severe-injury report for EOG Resources, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EOG RESOURCES, INC.
Site address
1396 CR 212
City
SMILEY
State
TX
ZIP
78159
Mailing
19100 RIDGEWOOD PARKWAY BUILDING 2, SAN ANTONIO, TX 78259
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211112
Employees
13
Ownership type
A

4 citations on file for this inspection.

1910.38 C02

Other-than-serious 1 instance 8 exposed
Issued
Feb 28, 2019
Abate by
Mar 6, 2019
Penalty
Initial $7,577 · Current $3,789 Reduced
29 CFR 1910.38(c)(2): The emergency action plan did not include the minimum elements of an emergency action plan listed in (c)(1) through (6) of this standard.    On or about 12 September 2018, and at times prior thereto, workers at the Smiley Hub were exposed to an explosive vapor cloud while mustered at the Assembly Point located just outside the front gate. The Employer had posted a sign indicating the location was the Evacuation Assembly Area, San Antonio Division, EOG Resources. The sign was contradictory to the written Emergency Action Plan (EAP), both in the Control Room and within the Plan.
Recent events (3)
  • — F (O) $3788.5
  • — C (S) $7577
  • — Z (S) $7577

1910.119 D03 I B

Other-than-serious 1 instance 8 exposed
Issued
Feb 28, 2019
Penalty
Initial $5,683 · Current $2,842 Reduced
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams.    On or about 12 September 2018, and at times prior thereto, piping and instrumentation diagrams did not reflect actual conditions in the facility.  a) H2S Detector: AIT 7401 located at H2S Station #13 was not reflected on P&ID SMLY-PID-1701, both in the initial company submission on 12 September 2018, and again on 14 February 2019.  b) MOCR SMY2016-063: P&ID SMLY-PID-1101 indicated this MOCR as a redline change as of 05/06/16 but had not been implemented in the field. The company was awaiting a plant shutdown in order to implement the physical change.
Recent events (3)
  • — F (O) $2841.5
  • — C (S) $5683
  • — Z (S) $5683

1910.119 D03 II

Other-than-serious 1 instance 8 exposed
Issued
Feb 28, 2019
Abate by
Oct 21, 2019
Penalty
Initial $13,260 · Current $6,630 Reduced
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.     On or about 12 September 2018, and at times prior thereto, equipment and piping involved in the process was not labeled or had illegible markings as per 1989 ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, UG-119(c)(2), NFPA 704, and ASME/ASAA13-1928, exposing workers within the processing area to explosion effects from overpressure, toxic atmosphere, fire and projectile hazards.   a) The nameplate on pressure vessel V-1405 (Flash Separator) was painted over, concealing the operating information for the vessel.   b) The piping system within the facility did not indicate the hazard, contents, flow direction, or chemical state of gas or liquid.
Recent events (3)
  • — F (O) $6630
  • — C (S) $13260
  • — Z (S) $13260

1910.147 C05 II D

Other-than-serious 1 instance 8 exposed
Issued
Feb 28, 2019
Abate by
Mar 6, 2019
Penalty
Initial $5,683 · Current $2,842 Reduced
29 CFR 1910.147(c)(5)(ii)(D): Lock-out devices and tag-out devices did not indicate the identity of the employee applying the device(s).    On or about 12 September 2018, and at times prior thereto, a lock and tag were utilized on HOA P-3605, Hands-Off Auto Switch for Pump 3605, without any identification as to who applied the lock and tag, when it was applied, for what purpose, or any remarks. Later, it was determined the tag and lock were meant to remind personnel to refill the pump with oil prior to operating the pump.
Recent events (3)
  • — F (O) $2841.5
  • — C (S) $5683
  • — Z (S) $5683

View EOG Resources, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343459111.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.