Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONTECH ENGINEERED SOLUTIONS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CONTECH ENGINEERED SOLUTIONS, LLC in 1110 STEVENSON DRIVE, SPRINGFIELD, IL 62703 (NAICS 326122). OSHA activity number 343460580.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Contech Engineered Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Contech Engineered Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1110 STEVENSON DRIVE
City
SPRINGFIELD
State
IL
ZIP
62703
Mailing
1110 STEVENSON DRIVE, SPRINGFIELD, IL 62703
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326122
Employees
39
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2018
Abate by
Dec 27, 2018
Penalty
Initial $12,934 · Current $12,934
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about September 11, 2018 an employee was exposed to amputation hazards associated with moving parts, during set-up activities of the "beller" head on line 5.  The employer failed to implement energy control application steps as the equipment was not shut down or turned of to perform the set-up activities [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $12934
  • — Z (S) $12934

1910.212 A01

Serious Gravity 5 1 instance 8 exposed
Issued
Dec 11, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about September 11, 2018, employees performing production operations on the Line #5 Belling system were exposed to amputation and caught-in hazards.  The expanded metal guard was held in place by wing-headed screws that required no tools to remove.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9239

View Contech Engineered Solutions, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343460580.