SIOUX FALLS, SD —
OSHA Inspection: A-1 JET, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A-1 JET, LLC in 3405 WEST EIDE DRIVE, SIOUX FALLS, SD 57107 (NAICS 327991). OSHA activity number 343460721.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A-1 JET, LLC
- Site address
- 3405 WEST EIDE DRIVE
- City
- SIOUX FALLS
- State
- SD
- ZIP
- 57107
- Mailing
- 3405 WEST EIDE DRIVE, SIOUX FALLS, SD 57107
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 8
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.37 A03
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $1,663 · Current $640 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from hazards associated with emergency egress of the shop area in that the southeast emergency exit door was obstructed by overhanging materials on a nearby pipe rack. This condition exposed employees to hazards associated with emergency egress of the shop area.
Recent events (2)
- — I (S) $640
- — Z (S) $1663
1910.37 B02
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from hazards associated with emergency egress of the shop area in that the southeast emergency exit door was not marked by a sign reading "Exit." This condition exposed employees to hazards associated with emergency egress of the shop area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.110 F02 II
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(f)(2)(ii): Propane containers when stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from fire hazards and hazards associated with emergency egress of the shop area in that propane cylinders used for the forklift onsite were stored in close proximity to the northwest emergency exit door of the shop area. This condition exposed employees to fire hazards and hazards associated with emergency egress of the shop area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $2,217 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was isolated from the energy source and rendered inoperative: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from caught-in, pinch-point, struck-by and similar hazards in that the company had not developed, implemented, and maintained an energy control program. This condition exposed employees to caught-in, pinch-point, struck-by and similar hazards.
Recent events (2)
- — I (S) $1300
- — Z (S) $2217
1910.212 A03 I
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $2,217 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(i): The employer did not ensure that the point of operation of machines whose operation exposes an employee to injury, was guarded: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from caught-in hazards when operation the Amada Bendamatic 100 in that the point of operation was not guarded to prevent employee injury. This condition exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $1300
- — Z (S) $2217
1910.213 C01
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from caught-in hazards in that Craftsman 10-inch contractor saw (Model: 351.218330, Code No: 2009.08) was not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut. This condition exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: (a) (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from struck-by hazards in that employees performed cross-cuts without the Craftsman 10-inch contractor saw (Model: 351.218330, Code No: 2009.08) not being equipped with kickback fingers. This condition exposed employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $1,663 · Current $640 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from chemical hazards in that the company had not developed, implemented and maintained a written hazard communication program. This condition exposed employees to chemical hazards.
Recent events (2)
- — I (S) $640
- — Z (S) $1663
1910.1200 F06
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from chemicals hazards in that not all hazardous chemicals in the shop were labeled or marked with the information under paragraphs (f)(6)(i) through (ii) of this section.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required safety data sheets for each hazardous chemical in the workplace: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from chemicals hazards in that the company did not retain safety data sheets for all hazardous chemical used onsite. This condition exposed employees to chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not ensure employees were protected from chemical hazards in that the employer did not provide effective information and training on hazardous chemicals in their work area. This condition exposed employees to chemical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Dec 6, 2018
- Abate by
- Feb 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The basic advisory information on respirators, as presented in Appendix D of this section, was not provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer: (a) A-1 Jet, LLC at 3405 West Eide Drive in Sioux Falls, SD 57107: On or about and at times prior to September 13, 2018, the employer did not provide employees who wear respirators when such use is not required by the employer with information on respirators as presented in Appendix D.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 327991)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343460721.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.